Mhz Deviation Adjustment (Vc-195 Board) - Sony Handycam CCD-TRV3E Service Manual

Video camera recorder
Hide thumbs Also See for Handycam CCD-TRV3E:
Table of Contents

Advertisement

2. 1.7 MHz Deviation Adjustment (VC-195 board)

Sets the spectrum of the R-ch ((L-R)/2 signal) level modulated during
recording. If deviated, the crosstalk signal of the audio signal will
occur and the audio level will drop during both playback and
recording.
Mode
VTR recording
Signal
Input the AFM DEV jig output signal to
the left and right audio input terminal
Measurement Point
CH1: AFM DEV jig TP32
CH2: AFM DEV jig TP2
Measuring Instrument
Oscilloscope
ADD mode
CH2 normal mode
Adjustment Page
F
Adjustment Address
46
Specified Value
The level difference between CH1 signal
and CH2 signal should be minimum.
Connection:
1) Connect TP24 and TP26 of the AFM DEV jig to CN910 of the
VC-195 board.
TP24 (GND) ..................... Pin 8 of CN910
TP26 (RF SWP) ................ Pin !¡ of CN910
2) Connect TP25 (REC AFM) of the AFM DEV jig to Pin @ª of
IC301 with a 0.01µF capacitor (1-101-004-00).
3) Connect the audio output terminal (J1 and J2) of the AFM DEV
jig to AUDIO terminal of the unit.
4) Connect TP28 (DC), TP27 (GND) of the AFM DEV jig to the
DC power supply (+7Vdc to +9Vdc).
5) Set the AFM DEV jig switches to the following positions.
S1 ............................... BIL Position
S2 ............................... NT Position (NTSC)
S3 ............................... INV Position
Preparations only for the model without REC switch:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to "1". (Refer to "3. Bit value discrimination"
of "3-1-8. Service mode").
3) Select page: D, address: 15, after memorizing the data , set the
bit value of bit7 to "0".
4) Set to recording mode. (Use the wireless remote commander
of 8mm VCR, or connect Pin 6 of CN935 of DD-95 board
and GND with 4.7kΩ registor for a second.)
4.7kΩ registor : 1-249-425-11
PAL Position (PAL)
Adjusting method :
1) Match the vertical ranges of CH1 and CH2 of the oscilloscope
to each other.
2) Set the oscilloscope to the ADD mode and CH2 to the normal
mode.
3) Select page: 0, address: 01, and set data: 01.
4) Select page: F, address: 46, change the data and minimize the
audio signal level difference (A).
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
Processing after completed adjustment: only for the model without
REC switch:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 14, and set the data memorized at step
2) of "Preparations only for the model without REC switch".
3) Press the PAUSE button of the adjusting remote commander.
4) Select page: D, address: 15, and set the data memorized at step
3) of "Preparations only for the model without REC switch".
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
Approx. 2msec
5-57
A
Fig. 5-3-24.