Stirrer Motor; Magnetron Thermal Cut-Out (Mag Tco); Cavity Thermal Cutout (Cavity Tco); Tray Replacement - Maytag ALD510D Service Manual

2006 international countertop commercial microwave ovens
Table of Contents

Advertisement

Disassembly Procedures
!
WARNING

Stirrer Motor

1. Disconnect power to oven.
2. Remove outer case.
3. Disconnect wire terminals from stirrer motor.
4. Remove screws securing stirrer motor to supporting
bracket.
5. Replace component and reverse procedure to
reassemble.
NOTE: When replacing stirrer motor, verify motor shaft is
aligned with antenna shaft before securing with
screws.

Magnetron Thermal Cut-Out (Mag TCO)

1. Disconnect power to unit.
2. Remove outer case, see "Outer Case" procedure.
3. Disconnect wire terminals from TCO.
4. Remove screws securing TCO to magnetron.
5. Replace component and reverse procedure to
reassemble.
NOTE: When reconnecting wiring to thermal fuses the
connectors must be tight.

Cavity Thermal Cutout (Cavity TCO)

1. Disconnect power to unit.
2. Remove outer case, see "Outer Case" procedure.
3. Disconnect wire terminals from thermal fuse.
4. Remove screw securing thermal fuse to oven cavity.
5. Replace component and reverse procedure to
reassemble.
NOTE: When reconnecting wiring to thermal fuse the
connectors must be tight.

Tray Replacement

1. Unplug oven from outlet.
2. Using a suction cup or a thin bladed screwdriver, pry
upward on front corners and remove tray from unit.
3. Thoroughly clean and degrease sump area.
4. Clean oven cavity bottom where new oven tray will
make contact using mineral spirits or any
nonflammable degreasing solvent.
NOTE: Detergents, soap, and water are not sufficient to
remove oil and grease.
5. Place new tray into unit.
©2006 Maytag Services
To avoid the risk of electrical shock, personal injury, or death,
disconnect power to oven and discharge the capacitors before
following any disassembly procedure.

Oven Light Assembly

The light bulb for inside of the oven can be changed only
by removing the outer case.
Follow these steps to change the bulb:
1. Disconnect power to unit.
2. Remove outer case, see "Outer Case" procedure.
3. Disconnect wire terminals from oven light socket.
4. Push securing tab to release oven light assembly and
lift upward to remove from interlock assembly bracket.
5. Replace component and reverse procedure to
reassemble.
NOTE: After replacing the oven light assembly, verify the
"Interlock Assembly" is properly aligned and
operating correctly.

Slow Acting Relay Assembly

1. Disconnect power to unit.
2. Remove outer case, see "Outer Case" procedure.
3. Disconnect wire terminals from relay assembly.
4. Remove slow acting relay assembly from interlock
assembly bracket.
5. Replace component and reverse procedure to
reassemble.

Air Guide

1. Disconnect power to unit.
2. Remove outer case, see "Outer Case" procedure.
3. Release plastic tabs securing top portion of light
cover to inner cavity side wall.
4. Lift upward on light cover to release bottom securing
tabs.
5. Replace component and reverse procedure to
reassemble.
16026969