Focus Actuator operating is
abnormal
Is there Focus
Search control signal input?
(IC501 pin 53)
YES
Is there Focus
Search drive voltage output?
(IC501 pin 45, 46)
YES
•
Check the connection of PN401 pin 1, 2.
•
Check the Pick-up Connector(PN401).
Replace the Pick-Up.
Spindle control is abnormal 1
(CD-ROM Disc)
Does FOCUS Servo
operate normally?
YES
Is there EFM signal input?
(IC201 pin 163)
YES
Go to "Spindle operating is
abnormal"
60
NO
•
Check the connection of IC201 pin 207.
•
Check the communication line between
IC201 and IC301.
•
Replace the IC201 (OTI-9797).
Aren't
NO
MUTE1 signal "H" and
MUTE2 signal "H"?
(IC501 pin 22, 23)
YES
•
Replace the IC501(BD7902C).
NO
Go to "Focus Servo is unstable"
NO
Is there output normally?
(IC401 pin 71)
YES
Replace C223 and IC201
(OTI-9797)
NO
•
Check the connection of IC201 pin
207.
•
Replace the IC201(OTI-9797).
NO
Replace the IC401(CXA2638R).