1.3 RM2201 OPERATION

115 Volt
SUPPLY
Thermostat
\
3
GAS OPERATION
A.
Rotate selector to "OFF" position.
1)
Turn gas handle to the left.
2)
Turn gas thermostat knob to #4 setting.
3)
Press gas safety valve plunger up and hold.
4)
Push piezo igniter plunger repeatedly until
5)
flame is observed at "6".
When flame is lit:
6)
a. Discontinue pushing the piezo plunger.
b. BUT continue to hold up on the safety
valve plunger for about 15 seconds.
c. If flame goes out when plunger is re-
leased, repeat Steps 4 through 6.
Turn the handle (8) of the gas valve (7) away
from the back of the cabinet to shut off gas
operation.
NOTE: The ice tray shelf should now show signs
of cooling after an hour. If the gas has to be re-lit
when the ice making compartment is still cold,
turn the thermostat dial (3) to MAX. Repeat
Steps 4 through 6 and, return the thermostat to
its normal setting only after the burner is lit.
The refrigerator has a flame failure device which
will automatically shut off the gas to the burner if
the flame is blown out. While the plunger (4) is
being held in, this device is temporarily inopera-
tive.
DANGER - DO NOT hold this plunger in
unless attempting to light the gas burner.
B. ELECTRIC OPERATION
1) Turn gas valve to "OFF" position (with the
handle pointing away from the cabinet).
2) Turn voltage selector switch so desired
voltage marking is next to the selector
position indicator.
For Example:
If 115 volt AC operation is desired, rotate
selector to "110-1 15V" position and connect the
115 volt electrical supply cord.
- or -
If 12 volt DC ooeration is desired, rotate selector
to "12V" position and supply 12 volt battery
power.
3) Turn the electric thermostat knob to #4
position.
The ice tray shelf should show signs of cooling
after about an hour.
TO SHUT OFF ELECTRIC OPERATION:
Rotate the voltage selector switch (2) to the
"OFF" position.