Important Note to the Owner Regarding
Product Warranty
Your warranty certificate is supplied as a separate document with
the unit installed by your contractor. Read the limited warranty
certificate carefully to determine what is and is not covered. Keep
the warranty certificate in a safe place. If you are unable to locate
the warranty certificate, please contact your installing contractor,
or contact customer service at 1-866-944-7575 to obtain a copy.
To receive the Lifetime Heat Exchanger Limited Warranty, good
for as long as you own your home, and the 10-Year Parts Limited
Warranty, online registration must be completed within 60 days of
installation. Online registration is not required in California or
Quebec.
Product limited warranty certificates for models currently in
production can be viewed at www.whirlpoolhvac.com. If your
model is not currently in production or does not appear on the
website, please contact your installing contractor or contact
customer service at 1-866-944-7575 to obtain a copy of your
warranty certificate.
To register your unit, go to www.whirlpoolhvac.com. Click on the
manufacturer's Comfort Commitment
the bottom center of the home page. Next, click on the Click
Here to Register Your Product link located at the top center of the
page, and complete the forms in the manner indicated.
WARNING
Goodman 49
To prevent property damage, personal injury or death due
to fire, do not install the furnace in a mobile home, trailer
or recreational vehicle.

Product Application

This furnace is primarily designed for residential home-heating
applications.
IMPORTANT:
This furnace is not designed or certified for use in mobile
homes, trailers or recreational vehicles.
This furnace is not designed or certified for outdoor
applications.
The furnace must be installed indoors (for example, attic
space, crawl space or garage area provided the garage area
is enclosed with an operating door).
This furnace can be used in the following nonindustrial
commercial applications:
Schools
Office buildings
Churches
Retail stores
NOTE: In such applications, the furnace must be installed with
the following stipulations:
It must be installed according to the installation instructions
provided and according to local and national codes.
It must be installed indoors in a building constructed on site.
It must be part of a ducted system and not used in a free air
delivery application.
It must not be used as a "makeup" air unit.
All other warranty exclusions and restrictions apply.
This furnace may be used as a construction site heater only if all
of the following conditions are met:
TM
Warranty link located at
Nursing homes
Hotels/motels
Common areas
Office areas
The vent system is permanently installed according to these
installation instructions.
A room thermostat is used to control the furnace. Fixed
jumpers that provide continuous heating cannot be used.
Return air ducts are provided and sealed to the furnace.
A return air temperature range between 60ºF and 80ºF (16ºC
and 27ºC) is maintained.
Air filters are installed in the system and maintained during
construction, replaced as appropriate during construction
and upon completion of construction.
The input rate and temperature rise are set according to the
furnace rating plate.
100% outside air is provided for combustion air requirements
during construction. Temporary ducting can be used.
NOTE: Do not connect the temporary duct directly to the
furnace. The duct must be sized according to the instructions
in the "Combustion and Ventilation Air Requirements"
section.
The furnace heat exchanger, components, duct system, air
filters and evaporator coils are thoroughly cleaned following
the final construction cleanup.
All furnace operating conditions (including ignition, input rate,
temperature rise and venting) are verified according to these
installation instructions.
NOTE: The Commonwealth of Massachusetts requires that the
following additional requirements must also be met:
Gas furnaces must be installed by a licensed plumber or gas
fitter.
A T-handle gas cock must be used.
If the unit is to be installed in an attic, the passageway to and
the service area around the unit must have flooring.
WARNING
Goodman 49
To prevent property damage, personal injury or death due
to fire, do not install the furnace in a mobile home, trailer
or recreational vehicle.
To ensure proper furnace operation, you must install, operate and
maintain the furnace in accordance with these installation and
operation instructions, all local building codes and ordinances. In
their absence, follow the latest edition of the National Fuel Gas
Code (NFPA 54/ANSI Z223.1), and/or CAN/CSA B149 Installation
Codes, local plumbing or waste water codes and other
applicable codes.
A copy of the National Fuel Gas Code (NFPA 54/ANSI Z223.1)
can be obtained from any of the following:
American National Standards Institute
1430 Broadway
New York, NY 10018
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley
Cleveland, OH 44131
A copy of the CAN/CSA B149 Installation Codes can also be
obtained from:
CSA International
178 Rexdale Boulevard
Etobicoke, Ontario, Canada M9W 1R3