8.1.10 S8 Comma dial modifier time
Command
Response
set
S8=<n>
read
S8?
<n>
Mandatory. V.25ter section 6.3.11. Value is given in seconds. See also D.
8.1.11 S10 Automatic disconnect delay
Command
Response
set
S10=<n>
read
S10?
<n>
Mandatory. V.25ter section 6.3.12. Value is given in tenths of a second. Values 0 and 255
(do not disconnect) are not in V.25ter.
8.1.12 L Monitor speaker loudness
Command
execute
L[0]..L3
Mandatory. V.25ter section 6.3.13. This setting is ignored.
8.1.13 M Monitor speaker mode
Command
execute
M[0]..M2
Mandatory. V.25ter section 6.3.14. This setting is ignored.
8.1.14 +DS Data compression
Command
set
+DS=<dir>,<neg>,<P1>,<P2>
read
+DS?
test
+DS=?
Mandatory when V.42bis data compression implemented. V.25ter section 6.6.1.
Parameters:
<dir> the desired direction(s) of operation of the data compression function; from the DTE
point of view:
0
Negotiated ...no compression
1
transmit only
2
receive only
3
both directions, accept any direction
<n> values
0..255 (default 2)
000..255
<n> values
0..255 (default 100)
000..255
Response
+DS: <dir>,<neg>,<P1>,<P2>
+DS: (0-3),(0,1),(512-2048),(6-32)
Default
0,0,2048,20
54/113