12.4.5 +FCC Capabilities parameters
Command
set
+FCC=<a>,
<b>,<c>,
<d>,<e>,
<f>,<g>,<h>
read
+FCC?
test
+FCC=?
TIA/EIA-592-A Section 8.5.1.1 /6/.
Value in S47 (ECM) affects to sixth and S48 (14.4k) to second parameter. Values of 1 and 2
makes still difference in S47 even when it is not shown when reading values. See chapter
6.1 and 16.2.
12.4.6 +FCQ Copy quality checking
Command
set
+FCQ=<n>,0
read
+FCQ?
test
+FCQ=?
TIA/EIA-592-A Section 8.5.2.3 /6/.
12.4.7 +FCR Capability to receive
Command
set
+FCR=<n>
read
+FCR?
test
+FCR=?
TIA/EIA-592-A Section 8.5.1.9 /6/.
12.4.8 +FCS Current session results
Command
set
read
+FCS?
test
TIA/EIA-592-A Section 8.5.1.3 /6/.
Response
<a>,<b>,<c>,<d>,<e>,<f>,<g>,<h>
S48=0: (0-1),(0-3),(0-4),(0-2),
(0-3),(0-1),(0-1),(0-7)
S48=1: (0-1),(0-5),(0-4),(0-2),
(0-3),(0-1),(0-1),(0-7)
Response
<n>,0
(0-1),(0)
Response
<n>
(0-1)
Response
<a>,<b>,<c>,<d>,<e>,<f>,<g>,<h>
Default
S47=0, S48=0: 1,3,0,2,0,0,0,0
S47=1, S48=0: 1,3,0,2,0,1,0,0
S47=2, S48=0: 1,3,0,2,0,1,0,0
S47=2, S48=1: 1,5,0,2,0,1,0,0
Default
1,0
Default
1
Default
0,0,0,0,0,0,0,0
89/113