Configuring The Interpreter's System - Bosch Integrus Installation And User Instructions Manual

Language distribution system
Hide thumbs Also See for Integrus:
Table of Contents

Advertisement

INTEGRUS | Installation and User Instructions | 6-Channel interpreter desk with loudspeaker
1.5 Configuring the interpreter's
system
The configuration of the 6-channel interpreter's system
is carried out independently of the CCS 800 system.
The controls located under the removable panel on the
desk must be pre-set before putting the system into
operation. To gain access to the controls, remove the
plastic protection cover and text plate located at the
top of the unit. This is achieved by inserting a small
pointed implement into the holes at either side of the
cover and carefully pushing forward to lever it off (see
figure 1.3).
Figure 1.3
Under-panel controls on the
LBB 3222/04 interpreter desk
A-select switch
The outgoing language distribution channel assigned to
each desk must be pre-set using the A-select 6-position
rotary switch. Each booth should be assigned a differ-
ent channel (1 to 6). The language assigned to each
channel can be written on the removable panel in the
spaces provided alongside the outgoing channel A indi-
cators. The appropriate LED will illuminate to indicate
which language is assigned to a particular desk. Factory
setting: channel 1.
Bosch Security Systems | 2005-04 | 9922 141 70164en
Set-up selector DIL switch 2
Switch
On
1
Channel B disable
2
Mic. OR2 disable
3
Interlock enable
4
Slave
5
Loudspeaker
OR2 disable
6, 7, 8
Not used
Figure 1.4
Factory setting of DIL switch 2
SW 2-1
B-enable - If desks are not to make use of
the B output, the B-enable switch must be
switched 'on'. The outgoing language distri-
bution channel for each desk will then be
determined by the A-select switch only
(regardless of the position of the A-B channel
selector key on the front panel).
SW 2-2
OR2 enable - To configure an auto-floor
system, the desk from which the transfer
interpretation will be made must have the
OR2 function enabled. The outgoing chan-
nel OR2 indicator will illuminate on this
desk. The B-enable switch must be 'off' for
this desk.
SW 2-3
Interlock - To prevent two or more desks
using the same outgoing channel, the inter-
lock feature can be enabled. When this
switch is 'on', the microphone will remain
inactive if an occupied outgoing channel is
selected.
SW 2-4
Master / slave - If more than one desk is
installed in a booth, the additional desks
must be set with this switch in the 'on'-posi-
tion. The first desk in a booth (that nearest
to the IR transmitter) must have this switch
in the 'off'-position. If only one desk is
installed in the booth, this switch must also
be 'off'.
en | 4
Off
Channel B enable
Mic. OR2 enable
Interlock disable
Master
Loudspeaker
OR2 enable