7. Click the Open (O) button on the computer screen.
The rewriting display appears in the system controller LCD.
If the software could not be rewritten, an error code appears
in the LCD.
If an error occurs, reset the computer (see "3-2. Resetting
the computer"), and then press the ENTER button and re-
peat the rewriting operation.
Caution:
If an error occurs, do not try to reset the computer by turn-
ing off the system controller power or pressing the RESET
button.
8. When software rewriting is complete, "REWRITE PROGRAM
COMPLETE" appears in the system controller LCD.
Press the ENTER button to the initial display appears in the
LCD.
9. Turn off the power, disconnect the serial cable, and then
install the panel to the rear of the system controller.
Error code
Rewrite mode setting disabled
13
14
Access to rewriting prohibition adress
15
Rewriting operation error
Timeout error when reading
16
20
" : " Data receiving error
ASCII code data error
21
Record type error
22
Checksum error
23
Data count error
25
Individual data error
26
Transfer timeout error
27
Filename error
30
Table of error code
3-4. RESET button
The following three items can be cleared using the RESET
button.
1. Clock (time)
2. Password code for security lock (cancels the security lock)
3. Status list
Contents
Computer screen
Send Text File
Look in:
File name:
Files of type:
All files (*.*)
Software rewriting mode
R E W R I T I N G . . .
A D D R E S S : 0 0 1 0
Software rewriting error indication
R E W R I T E P R O G R A M
E R R O R : 3 0
Software rewriting completion
R E W R I T E P R O G R A M
C O M P L E T E
Initial display mode
S A N Y O
- - : - - : - -
Wiring diagram for RS-232C interlink serial interface cable
Controller side
1
RD
2
TD
3
DTR
4
GND
5
DSR
6
RTS
7
CTS
8
9
- 9 -
Open
Cancel
C o n t r o l l e r
PC side
1
RD
2
TD
3
DTR
4
GNG
5
DSR
6
RTS
7
CTS
8
9
? X