Ipv4 Qos; Qos Tab - Sony Ipela SNC-WR630 User Manual

Hide thumbs Also See for Ipela SNC-WR630:
Table of Contents

Advertisement

MTU
Type the MTU value for the Ethernet port.
To obtain DNS server address
automatically
Select Obtain DNS server address automatically.
The Primary DNS server and Secondary DNS
server are assigned automatically.
Note
To obtain a DNS server address automatically, first
enable Obtain an IP address automatically
(DHCP) in the IPv4 setting, or Obtain IP address
automatically in the IPv6 setting.
Ask the network administrator whether a DNS
server address can be obtained automatically.
To specify the DNS server address
manually
Deselect Obtain DNS server address
automatically. Type the address in the Primary
DNS server and Secondary DNS server boxes.
Primary DNS server
Type the IP address of the primary DNS server.
Secondary DNS server
Type the IP address of the secondary DNS server, if
necessary.
OK/Cancel
See "Buttons common to every menu" on page 21.

QoS Tab

In this tab, you can mark the data traffic packets sent
from the device and configure the settings for QoS
control. Rules for the types of data traffic can be created
using IPv4 address, port number, protocol, etc. A
maximum of 10 rules can be registered.

IPv4 QoS

Enable
Select the checkbox to configure the QoS setting for
IPv4.
Rule
Used to register, edit and delete QoS.
No.
Select the number to use when registering on the QoS
table.
When you select a registered number, the registered QoS
information is displayed.
Network address
Enter the network address of the target on which to
perform QoS.
Subnet
Enter the subnet mask values of the target on which to
perform QoS.
Tip
The subnet mask value represents the number of bits
from the left side of the network address.
Protocol
Select the protocol.
Port
Enter the port number for the data traffic of the device
(e.g. HTTP:80).
DSCP
Set a value to mark the data traffic (0 ~ 63).
This value is set in the DSCP field included in the IP
header of the data traffic.
Set
Used when registering on the QoS table.
QoS is set according to the following procedure:
1
Select No. from No. and enter the necessary
conditions for Network address, Subnet, Protocol
and/or Port No..
2
Enter values in DSCP.
3
Click Set and configure the QoS.
Delete
select No. to delete the setting and click Delete.
Configuring the Network — Network Menu
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipela snc-wr600Ipela snc-wr632Ipela snc-wr602

Table of Contents