- Voltage Testing Hall Sensor from the Main PCB Assembly
1. Unplug power cord.
2. Remove rear panel.
3. Remove washer top.
4. Remove main PCB assembly cover as shown in chart below.
5. Locate the blue hall sensor 6 wire connector using wiring diagram wire colors as your guide.
6. Plug in power cord, close door, and press power button. DO NOT PRESS START!
7. Place meter leads on white and gray wires. You should read 10 to 15 Vdc output from the Main
PCB Assembly to the Hall sensor. If no 10 to 15 Vdc is measured the control board is defective.
8. Place meters leads on blue to yellow. Turn motor rotor slowly by hand. You should measure
Test
a pulsing 10 Vdc. Place meter leads on red to yellow. Turn motor rotor slowly by hand.
point
You should measure a pulsing 10 Vdc. If both tests measure a pulsing 10 Vdc, hall sensor and
harness OK. If either or both tests measures 9 to 10 volts, but does not pulse or change,
and
hall sensor has failed and must be replaced. IF zero (0) voltage is measured on either test,
check red and blue wires for continuity. Repair or replace harness as needed.
Result
(Hall
Sensor)
Test Points
Result
(1) to (2)
8-12 kΩ
(1) to (3)
8-12 kΩ
(1) to (6)
10-15 Vdc
(2) to (6)
10 Vdc
(3) to (6)
10 Vdc
40
(6)
(3)
(2)
(1)
Remarks
Voltage Input