Dell XPS M1710  Owner's Manual page 95

Dell xps m1710 notebook pc owner's manual
Hide thumbs Also See for XPS M1710 :
Table of Contents

Advertisement

 
Keyboard clock line failure —
For external keyboards, check the cable connection. Run the Keyboard Controller test in the Dell Diagnostics. See
 
Keyboard controller failure —
For external keyboards, check the cable connection. Restart the computer, and avoid touching the keyboard or the mouse during the boot routine. Run the
Keyboard Controller test in the Dell Diagnostics. See
 
Keyboard data line failure —
For external keyboards, check the cable connection. Run the Keyboard Controller test in the Dell Diagnostics. See
 
Keyboard stuck key failure —
For external keyboards or keypads, check the cable connection. Restart the computer, and avoid touching the keyboard or keys during the boot routine. Run
the Stuck Key test in the Dell Diagnostics. See
 
Licensed content is not accessible in MediaDirect —
cannot be played. See
Dell MediaDirect
 
Memory address line failure at address, read value expecting value —
A memory module may be faulty or improperly seated. Reinstall the memory modules and, if necessary, replace them. See Memory.
 
Memory allocation error —
The software you are attempting to run is conflicting with the operating system, another program, or a utility. Shut down the computer, wait 30 seconds, and
then restart it. Try to run the program again. If the error message still appears, see the software documentation.
 
Memory data line failure at address, read value expecting value —
A memory module may be faulty or improperly seated. Reinstall the memory modules (see Memory) and, if necessary, replace them.
 
Memory double word logic failure at address, read value expecting value —
A memory module may be faulty or improperly seated. Reinstall the memory modules (see Memory) and, if necessary, replace them.
 
Memory odd/even logic failure at address, read value expecting value —
A memory module may be faulty or improperly seated. Reinstall the memory modules (see Memory) and, if necessary, replace them.
 
Memory write/read failure at address, read value expecting value —
A memory module may be faulty or improperly seated. Reinstall the memory modules (see Memory) and, if necessary, replace them.
 
No boot device available —
The computer cannot find the hard drive. If the hard drive is your boot device, ensure that the drive is installed, properly seated, and partitioned as a boot
device.
 
No boot sector on hard drive —
The operating system may be corrupted. Contact Dell. See
 
No timer tick interrupt —
A chip on the system board may be malfunctioning. Run the System Set tests in the Dell Diagnostics. See
Dell
Diagnostics.
Dell
Diagnostics.
Dell MediaDirect™ cannot verify the Digital Rights Management (DRM) restrictions on the file, so the file 
Problems.
Contacting
Dell.
Dell
Diagnostics.
Dell
Diagnostics.
Dell
Diagnostics.

Advertisement