iNSTALLATiON
iNSTRUCTiONS
Instatl the shutoff valve on the nearest frequently
used
drinking
water line.
1. SHUT OFF THE MAIN WATER SUPPLY
Turn on the nearest faucet to relieve the pressure on the
line.
2. CHOOSE
THE VALVE
LOCATION
Choose
a location
for the valve that
is
easily
accessible,
it is best to connect
into the side of a vertical
water
pipe.
When
it is necessary
to connect
into
a horizontai
water
pipe,
make
the
connection
to the top or side, rather
than
at the bottom,
to avoid
drawing
off any sediment
from the water
pipe.
m
3. DRILL THE HOLE FOR THE VALVE
Drill a I/4 in. hole in the water pipe using a sharp bit.
Remove any burrs resulting from
drilling
the hole in the pipe. Be
careful not to allow water to
drain into the drill. Failure to
drill a 1/4 in. hole may result
in reduced
ice production
or
smaller cubes.
NOTE: The hookup line cannot be white, plastic
tubing. Licensed plumbers
must use only copper
tubing (NDA tubing #49595
or #49599)
or Cross Link
Polyethylene
(PEX) tubing.
4. FASTEN THE SHUTOFF VALVE
Fasten the shutoff valve to the cold water pipe with
the pipe clamp.
Pipe Clamp-
Saddle-Ty_
Shutoff Valve
Vertical
Cold
Water
Pipe
NOTE: Commonwealth
of Massachusetts
Plumbing
Codes 248CMR shall be adhered to. Saddle valves are
illegat and use is not permitted
in Massachusetts.
Consult with your licensed plumber.
5. TIGHTEN THE PiPE CLAMP
Tighten the clamp screws until the sealing washer
begins to swell.
NOTE: Do not overfighten
damp
or you may crush the
tubing.
Washer
Pipe Clamp
Clamp Screw_
,--------inlet End
o
7.
ROUTE THE TUBING
Route the tubing between the cold water line and the
refrigerator.
Route the tubing through a hole drilled in the wall or
floor (behind the refrigerator
or adjacent
base cabinet)
as close to the wall as possible.
NOTE: Be sure there is sufficient extra tubing (about
8 feet coiled into 3 turns of about 10 in. diameter) to
allow the refrigerator
to move out from the wall after
installation.
CONNECT THE TUBING TO THE VALVE
Place the compression nut and ferrule (sleeve) for
copper tubing onto the end of the tubing and connect
it to the shutoff valve. Make sure the tubing is fully
inserted into the valve. Tighten the compression nut
securely.
Saddle-Type
Shutoff Valve _
X
,
Packing Nu_
Outlet Valve--
b
ression Nut
Ferrule (sleeve)
NOTE: Commonwealth
of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves are
illegal and their use is not permitted
in
Massachusetts. Consult with your licensed plumber.