Issue 13.0
Program
Program Name
Number
14-01-27
Basic Trunk Data Setup – Caller
ID Refuse Setup
15-07-01
Programmable Function Keys
20-07-24
Class of Service Options
(Administrator Level) – Set/
Cancel Private Call Refuse
20-07-25
Class of Service Options
(Administrator Level) – Set/
Cancel Caller ID Refuse
40-10-06
Voice Announcement Service
Option – Set VRS Message for
Private Call Refuse (VRS Msg
Private Call)
The Caller ID – Flexible Ringing Flowchart below helps define programming:
2 - 262
Description/Comments
Define if the trunk will reject the
call by playing the VRS message
based on the Caller ID
information.
Assign function key 86 (Set
Private Call Refuse) to Enable/
Disable trunks which are set in
Program 14-01-27 to "1".
Assign function key 87 (Set Caller
ID Refuse) to Enable/Disable the
Caller ID Refusal (trunks) which is
set in Program 14-01-27 to "1".
Enable (1) or Disable (0) an
extension user ability to set or
cancel Private Call Refuse.
Enable/Disable an extension
ability to set or cancel Caller ID
Refuse.
Assign the VRS Message number
used as Private Call Refuse.
When Fixed message is set, VRS
message guidance is: Service
finished. Disconnect the line,
please.
UNIVERGE SV8100
Assigned Data
1
0 = Disable (No)
1 = Internal Dial
2 = Enable (Yes)
(default = 0)
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99
(Appearance Function
Code) (Service Code
752 by default)
0 = Off
1 = On
(default = 0 for
COS 1~15)
0 = Off
1 = On
(default = 0 for
COS 1~15)
0~101
(0 = No message)
(101 = Fixed message)
(default = 0)
Caller ID – Flexible Ringing
Level
2
3