Canon PowerShot A300 Service Manual page 48

Hide thumbs Also See for PowerShot A300:
Table of Contents

Advertisement

CHAPTER 2. TECHNICAL DESCRIPTION
Error Code
Name
E27
CF WRITE
TIME OVER
E30
POWER OFF
ERROR
E50
CF FORMAT
ERROR
E51
CF ACCESS
ERROR
E52
QUICK REVIEW
ERROR
Occurrence Conditions
Free area could not be secured in the
buffer for the photograph image within
the specified time in the continuous
shooting mode.
The camera power was turned OFF while
the image was being recorded to the CF
Card. (The error code is displayed when
the camera is next turned ON.)
* This error may occur after E23.
The CF Card could not be formatted
properly.
When image data cannot be read from
CF normally.
Review of the photograph image failed.
2-6
Cause and Probable Faulty Part
CF CARD
MAIN PCB ASS'Y
The battery or DC plug was removed
while the image was being recorded to
the CF Card.
→ Remedy: Restart the camera.
CF CARD
CF CARD
MAIN PCB ASS'Y