UX-G6/FS-G6
Detaching the capstan motor (Fig. 4)
1. Disconnect the capstan motor wiring.
2. Remove the two screws F securing the capstan
motor.
Detaching the mechanism (Fig. 5 to 11)
1. Head block
Remove the two screws G securing the head
block (when installing, attach to the return gear
arm).
2. Pinch roller assembly
(1) Remove the pinch roller return spring (used to
prevent particle build-up).
(2) Release the hook securing the pinch roller
arm and pull the assembly up.
3. Reel disk
Press in the tip and pull out the disk. The stopper,
reel feather, spring and reel disk are detached at
the sometime.
Fig. 6
2-36
F
F
Fig. 4
G
Fig. 5
Fig. 7
G

Hide quick links: