Troubleshooting - Blizzard Lighting Flurry Wash User Manual

Table of Contents

Advertisement

DMX Channel Values (5 Channel Mode)
Channel
Channel Value
1
000 <-> 255
2
000 <-> 255
000 <-> 007
3
008 <-> 134
135 <-> 239
240 <-> 255
000 <-> 007
008 <-> 021
022 <-> 035
036 <-> 049
050 <-> 062
063 <-> 076
077 <-> 090
091 <-> 104
105 <-> 118
4
119 <-> 132
133 <-> 146
147 <-> 160
161 <-> 174
175 <-> 188
189 <-> 202
203 <-> 216
217 <-> 230
231 <-> 243
244 <-> 255
5
Flurry Wash Manual Rev. A
Does...
Pan
Tilt
Dimmer/Strobe
Closed
100%-0% Dimming
Strobe (Slow-Fast)
Open
Color Macros
No Function
White
Red
Green
Blue
Cyan
Magenta
Yellow
Purple
Orange
Chartruese
Pink
Brown
Gold
Crimson
Violet
Crepe
Color Change Macro #1
Color Change Macro #2
Reserved
Page 15
Copyright (c) 2010 Blizzard Lighting, LLC

Troubleshooting

Symptom
Solution
Fixture Auto-
Check the fan in the fi xture. If it is stopped or moving
Shut Off
slower than normal, the unit may have shut itself off due to
high heat. This is to protect the fi xture from overheating.
Clear the fan of obstructions, or return the unit for service.
Beam is Dim
Check optical system and clean excess dust/grime. Also
ensure that the 220V/110V switch is in the correct position,
if applicable.
No Light Output Check to ensure fi xture is operating under correct mode, IE
sound active/auto/DMX/Etc., if applicable. Contact service
for more information.
Chase Speed
Check to ensure proper setup of speed adjustment.
Too Fast/Slow
No Power
Check fuse, AC cord and circuit for malfunction.
Blown Fuse
Check AC cord and circuit for damage, verify that moving
parts are not restricted and that unit's ventilation is not
obstructed
Slow Movement
Verify that 220V/110V switch is in the correct position, if
applicable. Also check that speed channels are set appropri-
ately.
No Response to
Verify that the fi xture is in "Sound Active" mode.
Audio
Adjust Audio Sensitivity, If Applicable.
Fixture Not
Make sure all connectors are seated properly and securely.
Responding /
Use Only DMX Cables.
Responding Er-
Install a Terminator.
raticly
Check all cables for defects.
Reset fi xture(s).
Intermittant
Check lamp for properly installation.
Lamp
Relamp, lamp may have reached end of life.
Remote Doesn't
Verify remote control cable is installed properly and securely.
Work
Verify remote is correct type (CA-9 or other as applicable.)
Fixture Moving
Verify proper mode of operation. Is the fi xture in "Auto"
On Its Own
mode?
If your problem isn't listed, or if problems persist,
please contact support: support@blizzardlighting.com.