Specifications; Outdoor Units - Daikin Super Multi Plus D-Series Service Manual

Table of Contents

Advertisement

Specifications

1. Specifications

1.1

Outdoor Units

Model
Cooling Capacity
Heating Capacity
Total Indoor Unit Capacity
Power Consumption
Running Current
Casing Color
Type
Compressor
Model
Motor Output
Model
Refrigerant
Oil
Charge
Type
Refrigerant
Charge
Cooling
Air Flow Rate
(H)
Heating
Type
Motor Output
Fan
Running Current
Power Consumption
Starting Current
Dimensions (H×W×D)
Package Dimensions (H×W×D)
Weight
Gross Weight
Cooling
Operation
Sound
Heating
Cooling
Sound Power
Heating
Liquid
Piping
Gas
Connection
Drain
Heat Insulation
No. of Wiring Connection
Total main piping and
Max. Interunit
Total main piping
Piping
Total branch piping
Length
Max. length for each
Necessity of Additional Charge H
Max. Installation Height Difference
Note:
1. H Refrigerant charge is required. (Chargeless piping length 0m)
2. The data are based on the conditions shown in the table below.
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB
8
RMXS112D7V3B
4HP
kW
11.2 (9,630)
(kcal/h)
kW
12.5 (10,750)
(kcal/h)
kW
5.5~14.5
W
A
kW
2.5
L
kg
m³/min
104 (3,671)
(cfm)
m³/min
107 (3,777)
(cfm)
W
A
W
A
17.6
mm
mm
kg
kg
dBA
51
dBA
53
67
mm
mm
mm
3 For Power Supply (Including Earth Wiring), 2 For Interunit Wiring (Outdoor Unit-BP)
m
115
m
m
60
m
kg/m
m
30 (Between Indoor or BP Unit and Outdoor Unit), 15 (Both between Indoor Units and BP Units)
Formula for calculation charge : R (kg)
R = Total length (m) of liquid pipe size at φ9.5×0.054 + Total length (m) of liquid piping size at φ6.4×0.022
Cooling
Indoor ; 20°CDB
Outdoor ; 7°CDB / 6°CWB
Outdoor Unit
Main Piping
BP Unit
Branch Piping
RMXS140D7V3B
5HP
14.0 (12,040)
16.0 (13,760)
7.0~18.2
Ivory White
Hermetically Sealed Scroll Type
JT100FCVD
3.0
DAPHNE FVC68D
1.6
R410A
5.1
104 (3,671)
107 (3,777)
Propeller
70+70
0.4+0.4
88+88
22.6
1,345×900×320
1,475×980×420
127
132
52
54
68
φ9.5 (Flare Connection)
φ19.1 (Brazing Connection)
φ18
Both Liquid and Gas Pipes
135
55
80
15
Necessary
Heating
Piping Length
Refrigerant Piping length : 7.5m
Level difference:0m
Indoor Unit
(Q0143)
SiEBE18-526
50Hz 230V
RMXS160D7V3B
6HP
15.5 (13,330)
17.5 (15,050)
8.0~20.8
3.5
110 (3,883)
109 (3,848)
24.9
54
56
70
145
90
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3