3.

SPECIFICATIONS

3.1 General Specifications

Item
Display section
Operating ambient
Other than
temperature
display section
Storage ambient temperature
Operating ambient humidity
Storage ambient humidity
Vibration resistance
Shock resistance
Operating atmosphere
*1
Operating altitude
Installation location
*2
Overvoltage category
*3
Pollution degree
Cooling method
Grounding
*1
Do not use or store the GOT under pressures higher than the atmospheric pressure of altitude 0m (0ft.).
Failure to observe this instruction may cause a malfunction.
When the air inside the control panel is purged by pressurization, the surface sheet may be lifted by high pressure. As a result,
the touch panel may be difficult to press, and the sheet may be peeled off.
*2
This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical
power distribution network and the machinery within the premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300V is 2500V.
*3
This index indicates the degree to which conductive pollution is generated in the environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.
0 to 50
0 to 55
(when horizontally installed), 0 to 50
-20 to 60
10 to 90%, non-condensing (WBT: 39
10 to 90%, non-condensing
Under
Conforms to
intermittent
JIS B 3502 and
vibration
IEC 61131-2
Under
continuous
vibration
Conforms to JIS B 3502, IEC 61131-2 (147 m/s
Must be free of lamp black, corrosive gas, flammable gas, or excessive amount of electro
conductive dust particles and must be no direct sunlight. (Same as for saving)
2000 m (6562 ft) max.
Inside control panel
II or less
2 or less
Self-cooling
Class D grounding (100
or less), to be connected to the panel when grounding is not possible.
Specifications
(when vertically installed)
)
Half-
Frequency
Acceleration
amplitude
5 to 8.4Hz
-
3.5mm
8.4 to 150Hz
2
-
9.8m/s
5 to 8.4Hz
-
1.75mm
8.4 to 150Hz
2
-
4.9m/s
2
, 3 times each in X, Y and Z directions)
3. SPECIFICATIONS
3.1 General Specifications
1
2
3
Sweep count
10 times each in
X, Y and Z
directions
4
-
5
6
7
8
3 - 1