Download Print this page

JRC JFV-700 Installation Manual: Input Of Water Temperature Data (nmea Type Sensor)

Color echo sounder.
Hide thumbs

Advertisement

Setup Procedure
Select "DISPLAY SETTING" from the main menu, then select "Display" for the cursor
from sub-menu "VRM" (the system is initially set to "Display"). For the operation, see
page 28 in the Instruction Manual.

2.9.3 Input of Water Temperature Data (NMEA type sensor)

The JFV-700/HP allows to connect a water temperature sensor designed for the NMEA
output format.
When a thermistor type water temperature sensor (see Section 2.8) is connected, display
of water temperature data from a NMEA type sensor is disabled.
Connecting procedure: See Figure 2.4.
Connect the J907 ‡A (NMEA +in) to "NMEA OUT" of the NMEA output from the ex-
ternal equipment.
Then, connect the J907 ‡@ (NMEA -in) to "NMEA GND" of the NMEA output from the
external equipment.
Display Setup
Select "INITIAL SETTING" from the FISH FINDER SETTING, select "DATA
OUTPUT" for the cursor from sub-menu "EXT. OUTPUT" then switch the
"NMEA0183" using the sub-menu "EXT. OUTPUT" (the system is initially set to
"NMEA0183").
For the operation, see page 59 in the Instruction Manual.
Note:
1.
The following pin number arrangement is the one seen
from the soldered surface side.
2.
Users are required to separately procure the connector as
an interface mounting part (stock code: 7ZZBS0006).
Figure 2.4 Connecting Temperature Input
30
Pin No.
signal
‚P
NMEA IN(-)
‚Q
NMEA IN(+)
‚R
DATA OUT
‚S
GND
‚T
NC
‚U
NC
‚V
NC