Connections & Installation

Multi-Drop Communication System

A system that employs the RM-P2580 as the controller.
The following figure shows a system that can accommodate up to eight cameras. (100 positions can be preset per camera.)
Camera 1
TK-C625
MACHINE ID: 01
Switch 8: OFF
(RX TERM)
Camera 2
TK-C625
MACHINE ID: 02
Switch 8: OFF
(RX TERM)
Camera 8
TK-C625
MACHINE ID: 08
Switch 8: ON
(RX TERM)
Remote control unit
8 ACable ConnectionsB (A pg. 16)
(Terminal side of Ceiling Mount)
Control signal cable
Coaxial cable
Connection of the control signal cable
(A twisted pair cable is recommended.)
Camera 1
TX +
A
TX -
B
CONTROL
RX +
C
terminals
RX -
D
Camera 2
TX +
A
TX -
B
CONTROL
RX +
C
terminals
RX -
D
Camera 3
TX +
A
TX -
B
CONTROL
RX +
C
terminals
RX -
D
Control signal cable
Coaxial cable
AC 24 V power
supply
A CAUTIONS
AC 24 V power
supply
A CAUTIONS
AC 24 V power
supply
A CAUTIONS
TO CAMERA
POWER
ON
RM-P2580
AC
INPUT
To the TO CAMERA terminal of
the RM-P2580 and to the next
camera
To the CAMERA INPUT terminal
of the RM-P2580
To AC 24V power supply
Listed class 2 input only
Power cable
A
RX +
RM-P2580
B
RX -
terminals
C
TX +
TX -
D
Each terminal on the camera and
the RM-P2580 is marked
,
or
. In order to facilitate
understanding and to avoid
connection mistakes, it is
recommended to connect the
terminals carrying the same marks.
Observe the following points when connecting
components together:
●Turn all the components off before proceeding.
●Read the instruction manuals of all components before
proceeding.
●For the types and lengths of connection cables, see
ACable ConnectionsB (A pg. 16).
●Do not connect the control signal cables in a loop.
CAUTIONS
●The AC 24 V power supply must be isolated from the
primary line. (ISOLATED POWER ONLY)
●In order to prevent an excessive current flow through
the power supply wire or camera due to a short circuit,
a fuse must be installed in the power supply line.
TO CAMERA
DATA I / O
RX+ RX- TX+ TX
TX-
COM
1
2
3
4
5
6
7
8
COM 9/1 10/2 11/3 12/4 13/5 14/6 15/7 16/8 COM
AUTO
OFF
VIDEO INPUT
1
2
3
4
5
1 2
3
4
5 6
7
8
1
2
3
4
5
ON
VIDEO OUTPUT
MONITOR OUTPUT 1
8 ASwitch SettingsB (A pg. 13)
(Setting switches are on the side of the Ceiling Mount)
ON
1
2
3
4
5
6
7
Switch 1 : Invalid (Set to OFF)
Switch 2 : Invalid (Set to OFF)
Switch 3 : Invalid (Set to OFF)
Switch 4 : ON
Switch 5 : OFF
Switch 7 : Invalid (Set to OFF)
Switch 8 : Set to ON only for the
camera connected at the
end of the control signal
cable. Set to OFF for all
other cameras.
Camera 1 monitor display at power ON
,
,
A<Procedures for Checking
Machine ID>B (A pg. 14)
UNIT
CAMERA
SERIAL-1
SERIAL-2
ALARM
COM
SW
COM
6
7
8
MONITOR
MONITOR
OUTPUT
OUTPUT
1
2
6
7
8
Machine ID
Set to the Video Input number of
RM-P2580.
(Setting procedures A pg. 14)
8
>>
<<
INITIAL PROCESS
PAN
: - - I - -
TILT
: - - I - -
PROTOCOL
DUPLEX I D - 01
Duplex display
ID No. display
9