Pulse Speed Selection - Panasonic KX-TA624 Installation Manual

Advanced hybrid system
Hide thumbs Also See for KX-TA624:
Table of Contents

Advertisement

4.2
System Programming
Description
Selection
Default
Programming
Conditions
Feature Reference

Pulse Speed Selection

An outside (CO) line set for pulse or call blocking mode in program
[401] "Dial Mode" can have two pulse rates, 10 pps (low) and
20 pps (high). This program sets the pulse speed for each outside
(CO) line which has set the pulse or call blocking mode.
• Outside (CO) line number: 1 – 6,
• Low Speed (10 pps) / High Speed (20 pps)
All outside (CO) lines – Low Speed
1.
Enter 402.
Display: Pulse Speed
2.
Press NEXT.
Display: CO NO? →
3.
Enter an outside (CO) line number.
Pressing NEXT also can enter outside (CO) line number 1.
Display example: CO 1:Low Speed
4.
Keep pressing SELECT until the desired selection is
displayed.
5.
Press STORE.
6.
To program another outside (CO) line, press NEXT or
PREV, or SELECT and enter the desired outside (CO) line
number.
7.
Repeat steps 4 through 6.
8.
Press END.
• To assign all outside (CO) lines to the same selection, press the
in step 3. In this case, the display will show: CO
• The required pulse speed is determined by the outside (CO) or Host
PBX line.
Section 3, Features
Dial Type Selection
(
= all outside (CO) lines)
:Mixed.
System Programming
402
key
4-63