Integration with Sony Network Camera
Communication Mode for Multipoint Connection
©2008 Sony Corporation
The operation specifications and the determined communication mode may vary
according to the user authority used for connection.
Some examples are provided below. ("PCS" in the table below refers to the main
terminal of the PCS-G50/G70.)
Operational Specifications 1: When only network cameras are connected as
sub-terminals
Condition
When sub-terminals are
1-a
connected within the
range of the LAN
bandwidth of the main
PCS
When sub-terminals
1-b
exceed the range of the
LAN bandwidth of the
main PCS
*
:
The PCS automatically switches communication modes not supported by the PCS (JPEG, dual codec, VGA, G.726,
1
30fps on H.264 and TCP) to a supported one.
VIDEO COMMUNICATION SYSTEM - TECHNICAL DOCUMENTATION
Operational Specifications
Determined Communication Mode
Authority
Administrator
When each setting on the main PCS's
Authority
network camera page is set to a setting other
than "Auto":
Connection is made using the setting values of
the main PCS. The operation mode and image
size are always determined by the PCS setting
values. (They cannot be changed
automatically.)
When each setting on the main PCS's
network camera page is set to "Auto":
In principle, operations follow each network
camera's setting
User
Regardless of the main PCS's network camera
Authority
settings, operations follow each network
camera's setting values.
Mixed
Cameras connected with the administrator
Administrator
authority and cameras connected with the
and User
user authority operate independently of each
Authority
other, with the specifications described above.
Administrator
When the bit rate exceeds the PCS's LAN
Authority
bandwidth, it is automatically changed to the
optimum rate regardless of the main PCS's
network camera settings.
User
When the bit rate exceeds the PCS's LAN
Authority
bandwidth, the mode is changed to "Voice Only"
from the added camera regardless of the main
PCS's network camera settings.
Mixed
When the bit rate exceeds the PCS's LAN
Administrator
bandwidth, it is automatically changed to the
and User
optimum rate for cameras connected with the
Authority
administrator authority, while the mode is
changed to "Voice Only" for cameras connected
with the user authority if capability exchange is
required again, regardless of the main PCS's
network camera settings.
Connection
1
values.*
February, 2008 / Ver 1.0
See
example
1-a-1(1)
See
example
1-a-1(2)
See
example
1-a-2
See
example
1-b-1
See
example
1-b-2
See
example
1-b-3
10