System unit
Antistatic
All electronic components and equipments are sensitive to static electricity. Even
precautions
small electrostatic discharges can render components useless or severely shorten
their working life, therefore preventive measures should always be taken.
No work should be carried on any item unless it is in a Special Handling Area (SHA)
as defined in BS CECC 00015:Part 1. In general this involves:
a common earth point
an earthed bench or bench mat
an earthed wrist strap
Equipment
The following tools are required to dismantle the system unit.
required
Philips screwdriver
Flat-bladed screwdriver
Nut spanner set
thin nosed pliers
System board
Many of the dismantling/reassembly procedures which follow involve the
connectors
disconnection and reconnection of system board plugs and sockets. The following
table gives, for each socket, the connector number which identifies it. This number
is printed on the system board next to each connector.
Connector
Parallel port
Token ring module
Hard disk drive power
Thick Ethernet
System board power
Hard disk drive control
Floppy disk drive
Loudspeaker
2/4 LS PRO HARDWARE TECHNICAL REFERENCE
Label
PL8
PL9 and PL16
PL12
PL13
PL15
PL17
PL18
PL40