Guidelines For Lead Free Solder - Brother HL-5130 Service Manual

Table of Contents

Advertisement

CHAPTER 4 DISASSEMBLY AND RE-ASSEMBLY

6. GUIDELINES FOR LEAD FREE SOLDER

All components are soldered using lead free solder, be sure to use lead free solder that
meets the following specification in the case of repair.
Lead free solder ; NIHON GENMA DHB-RMA3 NP303
(This can be distinguish from the lead free identification sign "LFH" on the MAIN PCB
ASSY REV.)
However, the solder side of the MAIN PCB ASSY and other PCBs are soldered using lead
content solder, use conventional lead content solder in the case of repair.
Since the reliability of soldering cannot be guaranteed if lead free solder and lead content
solder are mixed, take care not to use the incorrect solder or mix the solder types.
Information on Manually Repairing PCB Soldered with Lead-Free Solder
This document provides information on how to correctly make manual repairs to a printed circuit
board (PCB) soldered with lead-free solder.
1. Characteristics of lead-free solder
Melting point higher than that of conventional tin-lead solder
(Lead-free solder: approx. 220'C, Conventional tin-lead solder: approx. 180'C)
Relatively poor solder wettability and spread (difficult to wet and spread), and hard
Appearance (dull and grainy surface) different from that of conventional solder
Relatively poor wettability, rough surface (bumps are likely to be formed), and solder
dragging
Poor solder elevation
Poor thermal conductivity and heat resistant (difficult to melt)
2. Metal composition & wire solder
The metal composition of lead-free solder allowed for use on PCBs for Brother's products is
following.
LF
Indication
1
H
We use wire solder which is indicated by digit after LF indication on PCB.
Wire solder made in the contries except Japan are under investigation,and will be evaluated.
3. Appearance quality criteria
The appearance of the surface of portions soldered with lead-free solder is basically the
same as that for those soldered with conventional lead-tin solder, except for the following
points.
1) The surface of a portion soldered with lead-free solder is dull and not smooth.
2) Shrinkage cracks can be observed on the surface of a portion soldered with lead-free
solder. (They can be observed using a magnifying glass with approx. 10x
magnification.)
Compositon
Sn/Ag/Cu
only
Sn/Ag/Cu
Component-
side
Manufacture
r
Nihon
Genma
Nihon
Genma
4-68
Origin
Name
Japan
DHB-RMA3
NP303
Japan
DHB-RMA3
NP303

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hl-5140Hl-5150dHl-5170dn

Table of Contents