gardless of whether a disc is in the unit or not.
Panel full OPEN/CLOSE is conducted with a short-push.
(Protection time : 3 seconds)
As far as this item is concerned, eject will be achieved by 1
second long-push on the EJECT key.
Clearing Backup/Installer memory and CD mecha-
nism error log information (E2PROM data clear)
1. While pressing [Q] and [ATT] keys simultaneously, reset to
restart. This will initiate the initializing processes of backup/
installer memory and CD mechanism error log information.
2. When the initialization process is completed, the following
displays will be made.
Normal completion : "CD_O : AU_O_"
Abnormal completion1 : "CD_O : AU_X_" --- backup/in-
staller memory, initialization NG
Abnormal completion2 : "CD_X : AU_O_" --- CD mecha-
nism error log information, initialization NG
Abnormal completion3 : "CD_X : AU_X_" --- All initializa-
tion processes NG
3. While in this mode, even after an elapse of a pre-set time,
no backup memory items will be written to the E2PROM.
4. This mode is released by resetting. (What was on the last
screen will not be retained.)
Clearing DC error detection information (E2PROM
data clear)
1. While simultaneously pressing down on [3] and [6] keys,
reset the unit to enter the DC error display mode.
2. During STANDBY sourcing, the current DC error conditions
will be displayed.
When error detected : "DC_ERR__"
When error not detected : "DC_OK___"
3. While the error conditions are being displayed, short-press
[AUTO] / [TI] keys to clear the detection information.
(E2PROM clear)
4. DC Error Display mode is released by resetting. (What was
on the last screen will not be retained.)
Frequency spun switching (K / M type)
From the Power OFF condition, while pressing [1] and [5] keys
down simultaneously, press the [SRC] key and turn power ON.
TEST MODE
Security
• Forced Power ON mode (All models)
Even in the case where security is in effect, by simultaneously
pressing down on [Q] and [4] keys and resetting, it is possible
to turn the power on for 30 minutes only. After an elapses of
30 minutes, restart is possible only by resetting.
• How to register the security code after replacement of
the E2PROM (F/E) (Code security models)
1. Enter the test mode. (Refer to the section on "How to Enter
the Test Mode.")
2. Enter the MENU. While "SECURITY" is being displayed,
long-press
istration mode.
3. Using [FM] / [AM] /
[FM] key : Number up / [AM] key : Number down
key : Cursor Right /
4. Press
key for 3 seconds to display "RE-ENTER." Then,
re-enter the code using the method in above 4.
5. Press
key for 3 seconds to display "APPROVED."
6. Release the test mode. (Refer to the section on "How to
Release the Test Mode.")
Note : The security code for this model cannot be deleted
by "all clear" command.
• Simplified method of clearing security code
1. When you are requested to enter the security code, while
pressing down on [AUTO] key, use a long-press on
for 3 seconds. (----disappears.)
2. Using the remote controller, input "KCAR."
Press remote controller [5] key 2 times and then press
key. (Input for "K.")
Press remote controller [2] key 3 times and then press
key. (Input for "C.")
Press remote controller [2] key once and then press
key. (Input for "A.")
Press remote controller [7] key 2 times and then press
key. (Input for "R.")
3. The security is released and the unit enters the STANDBY
sourcing mode.
4. If a wrong code is input, the unit goes into the Code Re-
quest mode.
KDC-MP5028/MP528
/W6031/W6031Y
key for 1 second and enter the Security Reg-
/
keys, enter the code.
key : Cursor Left
key