KDC-MP5028/MP528
/W6031/W6031Y
MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
70
OEM_DISP_CE
70
NC
71
NC
72
P_CON
73
KEY_REQ
74
ANT_CON
75
ILLUMI_DET
76
BU_DET
77
ACC_DET
78
(PWIC_SVR)
79
PWIC_MUTE
80
PWIC_STBY
81
LX_CON
82
MUTE_PRE_R
83
MUTE_PRE_L
84
MUTE_0
85
MUTE_1
86
MUTE_2
87
LINE_MUTE
88
NC
89
PWIC_DC_DET
90
LX_RST
91
MUTE_C
92
NC
93
RDS_NOISE
94
AVSS
95
TUN_SMETER
96
VREF
97
AVCC
98
LX_DATA_S
99
LX_DATA_M
100
LX_CLK
10
Module
I/O
(functional)
EXTRA
I/O External display control request
O Not used. (M-destination only)
EXTRA
O Not used.
Power supply O External AMP control terminal
toPANEL
I
Communication request from VFD driver
EXTRA
O Power antenna control
EXTRA
I
Dimmer Illumi control
EXTRA
I
Momentary power down detection
EXTRA
I
ACC Power supply detection
PWIC
O SVR discharge circuit
PWIC
O Power IC MUTE terminal
PWIC
O Power IC standby control
LX_M
O Boot up request to slave unit
AUDIO
O PRE_OUT MUTE Rch
AUDIO
O PRE_OUT MUTE Lch
AUDIO
I/O E-VOL FRONT MUTE terminal
AUDIO
I/O E-VOL REAR MUTE terminal
AUDIO
I/O E-VOL OTHER MUTE terminal
EXTRA
I
Line mute detection
O Not used.
PWIC
I
DC Offset detection terminal
LX_M
O Hard resetting to slave unit
AUDIO
I/O E-VOL MUTE terminal (For AFS)
O Not used.
TUNER
I
FM noise detection terminal
µCOM
-
TUNER
I
S-meter output
µCOM
-
µCOM
-
LX_M
I
Data from slave unit
LX_M
I/O Data to slave unit
LX_M
I/O LX BUS clock
Truth
Application
Value Table
Processing Operation Description
External display
Output L-fixed
Output L-fixed
POWER ON : H, POWER OFF : L,
STANDBY source : L
Connect to VFD_PAN_DATA
TUNER ON : H
L : ON, H : OFF
With BU : L,
No BU, Momentary power down : H
With ACC : L, No ACC : H
When POWER OFF and momentary
power down, for 5 sec. : H, Then, : L
When STANDBY source and momentary
power down : L, When TEL MUTE : L
POWER ON : H, POWER OFF : L
H : Slave unit ON, L : Slave unit OFF
When CD MUTE R is L : H (When CD)
At momentary power down : H
Refer to timing chart. Only with 2-zone
and NAVI interruption : L-fixed
When CD MUTE L is L : H (When CD)
At momentary power down : H
Only with 2-zone and
NAVI interruption : L-fixed
L : MUTE ON, Hi-Z : MUTE OFF
L : MUTE ON, Hi-Z : MUTE OFF
L : MUTE ON, Hi-Z : MUTE OFF
TEL MUTE : 1V or less
NAVI MUTE : 2.5V or more
Output L-fixed
H : Reset, L : Normal
L : MUTE ON, Hi-Z : MUTE OFF
Output L-fixed
Connect to P_ON
Connect to VCC