Sanyo DSR-3716P Instruction Manual page 69

Digital video recorder with multiplexer function
Hide thumbs Also See for DSR-3716P:
Table of Contents

Advertisement

3
RECORD SET
2
Turn the jog dial to select setting (OFF,
for example), and then turn the shuttle
dial clockwise.
"REMAINING DISK WARNING" changes to "1%" from "**".
[Settings] (
indicates default setting)
Setting
Description
Recording is stopped when the normal recording area
OFF
becomes full.
Overwriting automatically starts from the beginning of
ON
the normal recording area when it becomes full.
.
Remaining disk
warning
If this is set to "OFF", the FULL indicator or ALARM
FULL indicator will start to flash when the remaining
hard-disk capacity reaches the percentage set for
"REMAINING DISK WARNING".
3
Use the same procedure to set "ALARM
RECORDING AREA" to "OFF".
4
Turn the jog dial to select "REMAINING
DISK WARNING", and then turn the
shuttle dial clockwise.
5
Turn the jog dial to set the remaining
capacity, and then turn the shuttle dial
clockwise.
The remaining capacity can be set anywhere between 1%
(default) and 10%.
<RECORDING CONDITIONS SET>
NORMAL RECORDING AREA
OVERWRITE
: OFF
ALARM RECORDING AREA
OVERWRITE
: ON
REMAINING DISK WARNING
: 1 %
SERIES REC
: OFF
AUTO DELETE
: OFF
<RECORDING CONDITIONS SET>
NORMAL RECORDING AREA
OVERWRITE
: OFF
ALARM RECORDING AREA
OVERWRITE
: OFF
REMAINING DISK WARNING
: 1 %
SERIES REC
: OFF
AUTO DELETE
: OFF
68
6
Press the [EXIT/OSD] button.
The setting procedure is ended and the display returns to
the normal screen.
EXIT/OSD
Turn "OVERWRITE" to "OFF" to display the remaining
memory for the current recording area on the operating
display.
Also, if remaining memory reaches the set percentage, the
FULL indictor flashes for normal recording area and the
ALARM FULL indicator flashes for the alarm recording
area. When the remaining memory runs out, the indicator
switches to a permanently lit condition and recording stops
automatically.
FULL indicator
Operation
display area
01-01-04 00:00:00 REC 1%
When the normal recording area or the alarm
recording area become full
Make a new "AREA FULL RESET" setting for "NORMAL
RECORDING AREA" and "ALARM RECORDING AREA"
on the <RECORDING AREA SET> screen. ( P.66)
ALARM FULL indicator
Remaining
capacity
display
EN A ALARM 0000
02
<RECORDING AREA SET>
TOTAL CAPACITY
:
82GB
NORMAL RECORDING AREA
:
80 %
AREA FULL RESET
->
ALARM RECORDING AREA
:
19 %
AREA FULL RESET
->
ARCHIVE AREA
:
1 %
AREA FULL RESET
->
CAUTION : WHEN THE AREA SETTING IS CHANGED,
THE WHOLE AREA WILL BE INITIALIZED !
English

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsr-3709p

Table of Contents