Purity And Convergence Adjustment - Sanyo CP21SE1(V) Service Manual

Hide thumbs Also See for CP21SE1(V):
Table of Contents

Advertisement

Purity and Convergence Adjustment

CAUTION: The Convergence and Purity adjustments have been made at the factory. Readjustment
should be made only after picture tube or deflection yoke replacement, following the steps below:
PURITY ADJUSTMENT
1. Demagnetize the picture tube and receiver using an external
degaussing coil. When replacing picture tube or deflection
yoke, mount deflection yoke and purity-convergence magnets
assembly properly, see figures 1 and 4.
2. Turn Red and Blue guns off and provide only Green raster.
Rotate Screen control to fully counterclockwise. Rotate Red
and Blue Bias controls fully counterclockwise. Slowly rotate
Green Bias control clockwise to produce Green raster.
3. Loosen the screw holding the Deflection Yoke and remove the
3 Rubber Wedges, and slide the Deflection Yoke fully forward.
4. Rotate and spread the Tabs of the two Purity Magnets to cen-
tre the vertical green belt in the picture screen. The Purity
Magnets are also adjusted to obtain vertical centring of the
raster.
5. Slowly slide the Deflection Yoke backward until a uniform
green screen is obtained.
6. Check the purity of the red and blue screens for uniformity,
turn off other colours to check this (use bias controls).
Readjust the yoke position if necessary until all screens are
pure.
7. Adjust each Bias control and screen control to obtain white
raster. Refer to Gray Scale Adjustment. If part of the picture
screen is coloured, adjust the Deflection Yoke position forward
or backward slightly.
Note: The form of deflection yoke changes with models.
PURITY
MAGNET
TABS
SIX-POLE
MAGNET TABS
Figure 1. Purity and Convergence Magnets
Adjust tabs angle to superimpose
blue and red vertical line.
RED
BLUE
Figure- 2 BLUE AND RED LINE MOVEMENT
DEFLECTION YOKE
FOUR-POLE
MAGNET TABS
ANGLE
OF TABS
FOCUS GAP
(G3-G4)
Figure 4. Deflection Yoke Movement
Adjust tabs together to
superimpose red and
blue horizontal line.
8. Tighten the mounting screw of the Deflection Yoke. Adjust
Convergence next.
CENTRE CONVERGENCE ADJUSTMENT
1. Use a dot crosshatch pattern signal.
2. Turn Red and Blue guns on and turn off Green gun. Adjust the
angle between the Tabs of the Four Pole Magnet 1 and 2, and
superimpose the Red and Blue vertical lines in the centre area
of the picture screen. Refer to figure 2.
3. Keeping the mutual angle of the Tabs of the Four Pole Magnet
turn them together to superimpose the Blue and Red horizon-
tal lines in the centre area of the picture screen. Refer to fig-
ure 2.
4. Turn Green gun on and adjust Six Pole Magnet 3 and 4 that
the Green line superimposed on the Red/Blue lines.
This is the same procedure used in steps 2 and 3.
Refer to figure 3.
OUTER AREA CONVERGENCE ADJUSTMENT
Slightly loosen the screw holding the Deflection Yoke. Adjust the
Deflection Yoke to converge the detail in the outer area (left side
and right side) of the picture screen by orbital movement of the
front of the Yoke, then secure the Deflection Yoke in appropriate
position by putting the wedges as illustrated. Tighten screw hold-
ing the Deflection Yoke.
RUBBER
WEDGE
DEFLECTION YOKE
MOUNTING SCREW
Adjust tabs angle to superimpose
red/blue and green vertical line.
GREEN
BLUE / RED
Figure- 3 BLUE/RED AND GREEN MOVEMENT
-18-
ANGLE OF MAGNET TABS
MAGNET TABS
Figure 5. Adjusting Magnet
Adjust tabs together to
superimpose red/blue
and green horizontal
line.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp21se1

Table of Contents