Cli: Configuring Snmp V1 And V2C Traps; Cli: Configuring Snmp V1 And V2C Trap Destinations - HP ProCurve 530 NA (J8986A) Management And Configuration Manual

Table of Contents

Advertisement

General System Configuration
Configuring SNMP
5-36
Enter the IP address in the Trap Destination IP Address field and enter one
3.
of the configured community names in the Community Name field.
Select [Update].
4.

CLI: Configuring SNMP v1 and v2c Traps

CLI Commands Used in This Section
Command Syntax
[no] snmp-server trap <trap>
show snmp-server
To send SNMP v1 and v2c traps to a management station, specify the host IP
address using the snmp-server host command and enable specific traps using
the snmp-server trap command.
ProCurve Access Point 530# configure
ProCurve Access Point 530(config)# snmp-server trap
radiusAcctUpdate
ProCurve Access Point 530(config)#

CLI: Configuring SNMP v1 and v2c Trap Destinations

CLI Commands Used in This Section
Command Syntax
[no] snmp-server host <host_ip_address | host_name>
<community-string>
show snmp-server
To send SNMP v1 and v2c traps to a management station, specify the host IP
address using the snmp-server host command and enable specific traps using
the snmp-server trap command.
ProCurve Access Point 530(config)# snmp-server host 192.168.
1.15 public
ProCurve Access Point 530(config)# snmp-server host 192.168.
1.19 public
ProCurve Access Point 530(config)#
CLI Reference Page
9-43
9-45
CLI Reference Page
9-40
9-45