Disassembly - Sony SAL75300 Service Manual

4.5-5.6/75-300 75-300mm f4.5-5.6 lens for dslr camera
Hide thumbs Also See for SAL75300:
Table of Contents

Advertisement

Ver 1.1 2007.02
NOTE FOR REPAIR
• Make sure that the flat cable and flexible board are not cracked of bent at the terminal.
Do not insert the cable insufficiently nor crookedly.
• When remove a connector, dont' pull at wire of connector. It is possible that a wire is snapped.
• When installing a connector, dont' press down at wire of connector.
It is possible that a wire is snapped.
• Do not apply excessive load to the gilded flexible board.
UNIVERSAL WRENCH
In case of the following notches or holes are located in the lens block, etc during disassembling/
assembling the lens, Use the universal wrench.
How to Use
Attach the chip-A or chip-B to the universal wrench.
For the notches: chip-A
For the holes:
Match the universal wrench to the holes or notches of the lens block, etc.
Match the universal wrench
to the width of holes or notches.
Fixed screw
When top of tip does not reach holes or notches because the fixed screw becomes obstructive,
replace the fixed screw to below.
+B 3X5 7-682-546-09
SAL75300 (4.5-5.6/75-300) (75-300mm F4.5-5.6)
Notches
Universal wrench
J-6082-609-A
chip-B
Chip
Fixed screw

2. DISASSEMBLY

Holes
Chip-A for
universal wrench:
J-6082-609-1
Chip-A
Universal wrench
Chip-B
Chip
2-1
Cut and remove the part of gilt
which comes off at the point.
(Be careful or some
pieces of gilt may be left inside)
Chip-B for
universal wrench:
J-6082-609-2
Chip-A
Notches
Chip-B
Holes

Hide quick links:

Advertisement

Table of Contents
loading