4
PARAMETER
4.1
Parameter list
The following parameters are used for the plug-in option (FR-A8AX).
The FR-A8AX does not function with the initial setting. When a value other than "9999" is set in Pr.304, digital input is enabled.
Set the following parameters according to applications.
Pr.
Pr.
group
300
D600
BCD input bias
301
D601
BCD input gain
302
D602
BIN input bias
303
D603
BIN input gain
Digital input and analog input
304
D604
compensation enable/disable selection
305
D605
Read timing operation selection
329
,
D606
,
Digital input unit selection
447
D620
Digital torque command bias
448
D621
Digital torque command gain
804
D400
Torque command source selection
Parameters which can be displayed when the plug-in option (FR-A8AX) is mounted.
For Pr.329, write is disabled during operation even when "2" is set in Pr.77. To change the parameter setting value, stop the operation.
Also, parameter clear is invalid.
The initial values differ for the FM type and CA type of the FR-A800 series.
NOTE
• For binary input, the input data is taken in hexadecimal, and for BCD code input, the input data is taken in decimal.
Name
Setting range
0 to 590 Hz
0 to 590 Hz, 9999
0 to 590 Hz
0 to 590 Hz, 9999
0 to 4, 10 to 14, 9999
0, 1, 10
0, 1, 2, 3
0 to 400%
0 to 400%, 9999
0, 1, 3 to 6
Minimum
setting
Initial value
increments
0.01 Hz
0 Hz
0.01 Hz
60 Hz/50 Hz
0.01 Hz
0 Hz
0.01 Hz
60 Hz/50 Hz
1
9999
1
0
1
1
1%
0
1%
150%
1
0
PARAMETER
Refer to
page
24
24
24
24
20,
26
21
25
26
26
26
4
19