SANTA FE ADVANCE INSTALLER'S AND OWNER'S MANUAL Table of Contents do not have access to the equipment. Do not allow children to play with or near the unit or in its air flow. Precautions ................1 • The Santa Fe Advance is designed to be installed indoors only. 1.
SANTA FE ADVANCE INSTALLER'S AND OWNER'S MANUAL 4. Unit Assembly 5. Installation 4.1 Installing Feet (Optional) 5.1 Location Included with your Santa Fe The Santa Fe Advance can be installed in a variety oflocations to Advance are four leveling feet. It meet the owner’s needs, but should beinstalled directly in the area is important to level the unit for to be dehumidified.
“dry” in rooms under 65°; doing so will result in long periods of ineffective dehumidifier run time. Quality humidity meters are available from Therma-Stor and are recommended to accurately monitor humidity levels. Please call 1-800-533-7533 to order.
See cleaning instructions below. Replacement filters can The Santa Fe Advance uses a refrigeration system similar to an air be ordered from Therma-Stor by calling 1-800-533-7533. conditioner’s to remove heat and moisture from incoming air and add heat to the air that is discharged. Hot, high pressure refrigerant The 1/4”...
SANTA FE ADVANCE INSTALLER'S AND OWNER'S MANUAL Evaporator coil frosted continuously, low dehumidifying capacity. refrigerant is cooled and condensed by giving up its heat to the air that is discharged from the dehumidifier. The refrigerant liquid 1 Dirty air filter or air flow restricted. then passes through capillary tubing which cause the refrigerant 2 Defrost thermostat loose or defective.
PREPARING THE SANTA FE ADVANCE FOR REMOTE HUMIDITY CONTROLLER Preparing Dehumidifier for Remote Humidity Controller The following instructions detail the dehumidifier disassembly, removal of high voltage controls, designation of high voltage wiring, and dehumidifier reassembly. WARNING! THESE OPERATIONS SHOULD ONLY BE CONDUCTED BY A LICENSED ELECTRICIAN! THE CONTROL THAT WILL BE INSTALLED MUST BE ABLE TO SWITCH/OPERATE AT 115 VAC! ALL ELECTRICAL CONNECTIONS SHOULD FOLLOW THE NEC REGULATIONS! Step 1.
Page 8
PREPARING THE SANTA FE ADVANCE FOR REMOTE HUMIDITY CONTROLLER Step 7. Remove the electrical box assembly from the Step 10. Remove humidity control switch from the styrofoam case. Electrical box is taped to Styrofoam. electrical box. You may need to pull firmly. Do not lean, pry, or press anywhere on the Styrofoam case! You may damage the Styrofoam case.
Page 9
PREPARING THE SANTA FE ADVANCE FOR REMOTE HUMIDITY CONTROLLER Step 15. Place top cover back on the dehumidifier. Wiring After Changes Install front cover plate with the same screws removed 115 VAC, 60 Hz, SINGLE PHASE in step 3. Be careful not to over torque the screws. FAN MOTOR FAN SWITCH FAN ON...
CONDENSATE PUMP ASSEMBLY INSTRUCTIONS FOR SANTA FE ADVANCE Santa Fe Advance Condensate Pump Kit Assembly Instructions Note: Before attaching pump assembly, ensure that the dehumidifier has either the casters or leveling legs installed in it. These will be needed for additional height.
8" COLLAR ASSEMBLY FOR SANTA FE ADVANCE Step 1. Position collar on a flat surface with tabs up. Step 2. Position collar into large hole. Press firmly so that Collar tabs of collar go through the plenum hole. Sheet metal plenum Step 3.
SANTA FE ADVANCE DUCT KIT ASSEMBLY Santa Fe Advance Duct Kit Assembly Instructions Do not drill any pilot holes into the plastic housing. You may damage the internal components. When installing screws, be careful not to strip. Lightly tighten screws. Step 1 Step 2 FRONT DUCT ASSEMBLY: REFER TO FIGURE 1...
If the End-user is unable to locate or obtain warranty PERSONAL PROPERTY. service from an authorized technician, he should call Therma-Stor LLC at the above number and ask for the Some states do not allow limitations on how long an Service Department, which will then arrange for covered implied warranty lasts, and some do not allow the warranty service.
Need help?
Do you have a question about the Santa-Fe Advance and is the answer not in the manual?
Questions and answers