Epson Stylus Pro GS6000

4.4.7 Sensors

4.4.7.1 PF ENCODER ASSY
C H E C K
When removing the IH COVER on the left, remove six screws only.
P O I N T
See Figure 4-25.
1.
Remove the TOP COVER (left only).
2.
Remove the MAINTE COVER T.
3.
Remove the SIDE COVER (left only).
4.
Remove the REAR PAPER GUIDE.
5.
Remove the SPINDLE GUIDE COVER.
6.
Remove the IH COVER (left only).
7.
Remove the PF ENC
SCALE.(p155)
8.
Disconnect connector J2 from the SUB_C BOARD ASSY.
9.
Release the cable from the two clamps at the rear.
As seen from the rear
SUB_C BOARD ASSY
J2
Figure 4-82. Releasing the cable
DISASSEMBLY & ASSEMBLY
(p85)
(p88)
(p89)
(p96)
(p97)
(p90)
Clamp
Clamp to turn
Disassembly and Assembly Procedure
When routing the cable at the rear, make sure to give it one turn
around the marked clamp.
10. Release the cable from the three clamps and the one retainer on the left side.
11. Remove the two screws.
A) Silver, Phillips, Bind machine screw M2x10: two pieces
12. Press the part beside the pin to disengage the hook behind the sensor, and remove
the PF ENCODER ASSY.
As seen from the left
As seen from the left
PF ENCODER ASSY
Figure 4-83. Removing the PF ENCODER ASSY
Revision F
See Figure 4-82.
PF ENCODER ASSY
Pin
Push here
A
Retainer
Clamp to turn
Clamps
Confidential