Menu
Item
( c on t.)
To access
this menu,
hold [Enter]
(OF = offset)
pressed for
a few
seconds
Options
Notes (Default settings in bold print)
Prism off
Prism on, no rotation
Prism on: rotation CW and CCW; fast, medium and slow
–
Iris diameter: Press [Enter], then use up and down arrows to select
a value from 0 - 200
Iris closed
Fast opening pulse
Slow opening pulse
Fast closing pulse
Slow closing pulse
Fast random opening pulse
Slow random opening pulse
Fast random closing pulse
Slow random closing pulse
Focus position
–
Zoom position
–
Pan position
–
Pan position (fine)
–
–
Tilt position
Tilt position (fine)
–
Run a general test of all effects (for use by service technicians only)
Enable pan/tilt position correction system. See page 15
Disable pan/tilt feedback. Setting not saved
Enable position feedback from rotating effects. See page 15
Disable position feedback from rotating effects. Setting not saved
See "Adjustment submenu" on page 38
Pan calibration (adjustment range: 1 - 255)
Tilt calibration (adjustment range: 70 - 186)
Dimmer calibration (adjustment range: 90 - 170)
Color wheel 1 calibration (adjustment range: 103 - 153)
Color wheel 2 calibration (adjustment range: 103 - 153)
Gobo wheel 1 (rotating gobos) calibration (adjustment range: 103 -
153)
Gobo wheel 2 (static gobos) calibration (adjustment range: 103 -
153)
Focus calibration (adjustment range: 105 - 158)
Zoom calibration (adjustment range: 105 - 158)
Iris calibration (adjustment range: 128 - 255)
Prism calibration (adjustment range: 116 -140)
Set all effects to calibration value 128
PCB test: for service use only
Cooling fans: full speed
Cooling fans: temperature regulated
Manually set fixture to software update mode
Table 2: Control menu
Control menu