Installation Instructions; Verify Package Contents; Installing The Cooktop; Connecting The Gas Line - Dacor Preference PGM304-1 Installation Instructions Manual

Preference
Hide thumbs Also See for Preference PGM304-1:
Table of Contents

Advertisement

Verify Package Contents

Literature
Hold down brackets (2)
Cleaning kit (stainless steel models only)
Grates
Burner sets (4 for model PGM304-1, 5 for model
PGM365-1)
Gas pressure regulator

Installing the Cooktop

Verify that the power supply meets the specifications
on page 3 before proceeding.
To prevent damage to the gas pressure regulator,
install it only after the cooktop is mounted in its per-
manent position.
IMPORTANT
Do not over-tighten the hold down bolts. Over tight-
ening the hold down bolts may result in improper
operation of the dual gas burners.
Do not use a hardening compound or caulk to perma-
nently seal the cooktop into place. The cooktop must
be readily removable if service is required. Removal
of sealant to service the unit will be performed at the
customer's expense.
1.
Lower the cooktop into the cutout and center it.
2.
Secure the cooktop to the countertop using the two (2)
provided hold-down brackets as shown.
PGM Hold Down
Bracket Mounting Holes
6

Installation Instructions

WARNING
(both sides)
Gas Inlet
Electric Cord
Hold Down

Bracket Installation

Connecting the Gas Line

Verify that the gas supply meets specifications before
connection. See page 3.
Do not install or use the cooktop without the included
gas regulator installed.
Ensure that the arrow on the regulator points in the
direction of the gas flow, towards the cooktop.
Do not apply excessive pressure when tightening gas
connections and fittings.
Do not use Teflon tape or plumber's putty on flexible
gas line connections.
Test the gas lines for leaks as instructed before use.
Do not use a flame to check for leaks.
The maximum gas supply pressure to the regulator
must never exceed ½ pounds per square inch (psi)
or 3.5 kPa.
The cooktop and shut-off valve must be disconnected
from the gas supply piping during any pressure test-
ing exceeding ½ psi (3.5 kPa).
For LP gas installations, the LP gas tank must have
its own high-pressure regulator in addition to the
pressure regulator supplied with the cooktop.
1.
Attach the gas pressure regulator (included with the
cooktop) to the cooktop pipe nipple inlet. For tight
installations, the regulator may be installed upstream
from the pipe nipple, anywhere between the shut-off
valve and the cooktop. For best performance, minimize
gas pressure loss by attaching the regulator as close
as possible to the cooktop gas inlet.
2.
Complete connection of the gas supply to the cooktop
by installing a minimum ½" flexible gas line (not includ-
ed) between the pressure regulator and the shut-off
valve.
3.
Check for gas leaks:
Turn all cooktop control valves to the
Turn on the gas supply valve and check all lines
and connections for leaks using a soap and water
solution or a gas leak detector.
Turn the gas supply off.
WARNING
OFF position.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Preference pgm365-1

Table of Contents