3. Diving with Galileo
support diving with more than one gas
mixture. If you set the screen confi guration
to LIGHT and then program more than one
gas, Galileo will automatically switch to the
CLASSIC lay-out.
NOTE:
Only the shorter between no-stop
time and RBT is shown in LIGHT
confi guration. If your remaining gas
supply is such that you will enter
level stops or deco prior to reaching
an RBT of 0 minutes, the no-stop
time will be displayed on the screen,
emphasized by the NO STOP label. If
on the other hand your remaining gas
supply is such that you will reach RBT
of 0 minutes while still in the no-stop
phase, then the RBT will be displayed
on the screen, emphasized by the
RBT label.
More specifi cally, the following information
is displayed:
- current depth
- dive time
- the shorter between no-stop time and
RBT
- tank pressure
- nitrogen loading (via bar graph)
! WARNING
After a PRESSURE SIGNAL LOST warning,
Galileo is not able to compute the RBT any
longer. In such case, the LIGHT confi guration
shows the no-stop time but this does not imply
that you have enough gas supply to remain at
that depth for that amount of time.
Upon pressing the middle button (marked
MORE), you can retrieve alternate information.
This information appears instead of the tank
pressure and stays on the display only for
4 seconds, after which the tank pressure
is shown again. The alternate information
appears in the following sequence:
- maximum depth
- O
%
2
- temperature
- heart rate
52
- buddy tank pressure (only if BUDDY
tank designation has been paired, see
section 1.11)
- (active MB level if different than L0)
- (no-stop information relative to L0 if an
MB level between L1 and L5 is active,
see section 3.5.3)
- time of day
- CNS O
2
Each time you press the button the
information changes to the next one in the
sequence and stays there for 4 seconds
before reverting to the tank pressure. If you
press the MORE button again after the
fi eld has reverted to your tank pressure, the
sequence of additional information will pick
up again from the last displayed data.
3.3.4 FULL screen confi guration
This screen confi guration is meant for
those divers that prefer to have as much
information as possible displayed at once.
More specifi cally, the following information
is displayed:
- current depth
- dive time
- no-stop time (only during no-stop phase
of dive)
- deepest stop, duration of deepest
stop, total ascent time (only during
decompression phase of dive)
- tank pressure