Command Format:
15 14 13 12 11
10
9
8
7
6
5
4
3
o
o
1 0 1 0 1 1 1 1 1 1 1 0 1 0 1
OP SIZE
01010101010\
Command Sequence:
Operand Data:
A single operand is data to be written to the memory location. Byte data is
transmitted as a 16-bit word, justified in the least significant byte; 16- and 32-
bit operands are transmitted as 16 and 32 bits, respectively.
Result Data:
Status is returned as in the WRITE command: $OFFFF for a successful
III
operation and $10001 for a bus or address error during write.
7.2.8.12 Resume Execution (GO)
The pipeline is flushed and refilled before normal instruction execution is
resumed. Prefetching begins at the return PC and current privilege level. If
either the PC or SR is altered during BDM, the updated value of these registers
is used when prefetching commences.
CPU32 REFERENCE MANUAL
DEVELOPMENT SUPPORT
MOTOROLA
7-27