Figure 8.2.6 Overview Of End User Parameters - Hamworthy F40V Installation, Commissioning And Operating Instructions

Fleet series boilers
Table of Contents

Advertisement

Press one of the line selection buttons.
This will take you to programming level <<Enduser>>
Press the line selection button to choose the relevant line.
The display shows <<Pxxx>>
Adjust the required value with one of these buttons. The adjustment is stored as
soon as you change to some other line (to alter individual items, a change of
parameter is required).
The Enduser Parameter list details all possible settings.
Press button to leave the programming level.
Changes will not be stored
Press the Info button to leave the programming level.
Changes will be stored
Note: If no button is pressed for about 8 minutes, the screen will automatically return to the default display.
Changes will not be stored. When switching to another level, changes will be stored.
Line
Function
Time of day
1
Time of day
Setpoints
5
Reduced room temperature setpoint «TrSollRed» or
(reduced boiler temperature setpoint «TvSollRed»)
(When using an additional room unit, line 5 will be hidden)
Time program HK1 (heating circuit 1)
11
Time program HC1 switch-on time 1
12
Time program HC1 switch-off time 1
13
Time program HC1 switch-on time 2
14
Time program HC1 switch-off time 2
15
Time program HC1 switch-on time 3
16
Time program HC1 switch-off time 3
8.2.7 - Start-up / initialisation
On startup after power-On, or after a lockout reset, the setpoints will be initialized.
These setpoints apply until a first adjustment is made (e.g. via the screen display or PC parameterization):
After a readjustment, these values will be overwritten with the new value and permanently stored in the LMU.
When a new startup is made, or after power-On, the previous settings will be stored in the LMU.
Also, the software version number of the operator module and that of the connected type of LMU... will be
delivered.
8.2.8.1 - Chimney Sweep function
The chimney sweep function enables the boiler to be started up in heating mode by pressing both
buttons simultaneously for more than 3 seconds but for no more than 6 seconds.
On the
display, the upper arrow of the maintenance function flashes and the currently selected
temperature appears. This function serves for making measurements on the boiler. When the chimney sweep
function is activated, the boiler will deliver maximum output until the limit thermostat cuts out.
To ensure maximum supply of heat, the chimney sweep function generates the forced signal for heat supply.
During the time that the Chimney Sweep is activated, an appropriate status code is delivered.
To close the function, press button
HAMWORTHY HEATING LTD
st
period
st
period
nd
period
nd
period
rd
period
rd
period
29
FLEET V series
Range
Unit
0...23:59
h / min
TRF...TRN
°C
00:00...24:00
hh:mm
00:00...24:00
hh:mm
00:00...24:00
hh:mm
00:00...24:00
hh:mm
00:00...24:00
hh:mm
00:00...24:00
hh:mm
Figure 8.2.6 - Overview of Enduser parameters
Resolution
Default value
1 min
---
0.5
16.0
10 min
06:00
10 min
22:00
10 min
24:00
10 min
24:00
10 min
24:00
10 min
24:00
500001213/G

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

F50vF70vF85vF100vF125vF150v ... Show all

Table of Contents