Mapped External Lu Status Values - HP StorageWorks XP12000 User Manual

External storage xp
Hide thumbs Also See for StorageWorks XP12000:
Table of Contents

Advertisement

Table 8
External array status values (continued)
LU status
Warning
Checking
Cache Destage
Disconnect
• LDEV Status: Mapped external LU's status. Possible values: Normal, Unknown, Blockade, Warning,
and Format.
Table 9

Mapped external LU status values

LDEV status
Normal
Unknown
Blockade
Warning
Format
Product name of the connected external array
• ExG: External LU group number. This appears when you group the LUs from one or more external
arrays under a common number.
• Serial: Product serial number.
• Product: Product name.
• Vendor: Vendor name.
• Ex-Dev. Status: Status of the operation executed on the external array, or status of the path
connection. Possible values: Normal, Unknown, Blockade, Warning, Checking, Cache Destage,
and Disconnect. For a description of these values, see
• LDEV Status: Mapped external LU's status. Possible values: Normal, Unknown, Blockade, Warning,
and Format. For a description of these values, see
External LU group number
• Characteristic: External LU's identification number.
• Device: External LU's device name.
• Capacity: External LU's capacity in 512-byte blocks.
• Ex-Dev. info.: External array information. When the external array is an XP1024/XP128 or
TagmaStore Workgroup Modular Storage (WMS) array, an asterisk (*) appears.
• VMA: Information about the VMA setting by LUN Security XP Extension. When VMA is set for the
volume, an asterisk (*) appears.
• Alter. Path: Number of configured paths in the format The number of valid paths (the number of
primary alternate paths).
• IO Suppression: I/O Suppression mode: Enable or Disable. For more information, see
attributes set by
mapping" on page 20.
• Cache Mode: Cache mode: Enable or Disable. For more information, see
by
mapping" on page 20.
• Path: When paths are set, an asterisk (*) appears.
• Group: External LU group number and reference number assigned to each LU in the external LU
group. External Storage XP automatically assigns reference numbers to LUs in the group when
external LUs are mapped. This appears in the format "external LU group number - reference
number of the LU in the group".
Description
FC path or paths have an abnormal status. Check the status of the paths.
External Storage XP is verifying configuration information defined for FC paths.
External Storage XP is writing all data in the local array cache memory to the LU.
Connection to external array or external LU was intentionally stopped using the
Disconnect Subsystem or Disconnect Volume command.
Description
LDEV status is normal.
LDEV status has yet to be ascertained.
I/O traffic to the LDEV is not permitted.
External LUs have abnormal status.
Volume is in the process of being formatted.
Table
8.
Table
9.
"External LU attributes set
External Storage XP user guide
"External LU
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp10000Storageworks svs200

Table of Contents