F30 code for slide-in range

Advertisement

Quick Links

SERVICE FLASH
C K 0 7 6
M O D E L / S E R I A L #
P R O B L E M
C A U S E
S O L U T I O N
F30 Code for Slide-In Range
CGLES389FB1
CGLES389F89
CGLES389FB2
CGLES389FFS
CGLES389FB3
CGLES389F3
CGLES389FBC
CPLES399EC5
CGLES389FBG
CGLES389EC6
CGLES389FBL
CGLES389EC7
CGLES389FBE
CGLES389ECG
CGLES389FBS
CGLES389ECL
CGLES389FB8
CGLES389ECE
CGLES389FB9
CGLES389ECS
CGLES389FBF
CGLES389EC3
CGLES389FCG
CGLES389EC8
CGLES389FLE
CGLES389EC9
CGLES389FS3
CGLES389ECF
F30 fault code in EOC display.
Open oven temperature sensor circuit.
Note: The temperature sensor circuit consists of the sensor (probe), front safety thermostat,
rear safety thermostat and connecting wires.
On the above listed models this error code can be caused by one or more of the following
conditions.
1.
The oven temperature sensor (probe) is open.
2.
Front oven safety thermostat is open.
3.
Rear oven safety thermostat is open.
4.
Failed connection or broken wire in the sensor circuit.
Step 1: Test the resistance of the entire sensor circuit by disconnecting power to the range and
accessing the multi-pin harness connector plug on the rear of the EOC. With the plug discon-
nected from the EOC, measure the resistance between the two violet wires found in the har-
ness. At room temperature the resistance should be approximately 1100 ohms. If the resist-
ance is correct then the fault is internal in the EOC and it must be replaced.
Step 2: If the sensor circuit resistance is higher than 1200 ohms at room temperature, then
test the two safety thermostats in the oven sensor circuit. If either safety thermostat is found to
be open, it should be replaced with the proper service replacement part.
The safety thermostats may have a reset button that can be used to temporarily restore the
range to full function, however; the thermostat must be replaced for continued proper operation.
Note: The thermostat located in front must be replaced with p/n 318005213.
Note: If the rear safety thermostat is open there could be a failure of the cooling fan high
speed control thermostat p/n 318003614, or the cooling fan itself. This thermostat switches the
cooling fan from low speed to high speed when it reaches a temperature of 170°F. Verify that
the thermostat is operating properly by using a heat gun to raise the temperature above 170°F.
Select a bake cycle on the EOC and check to see that the cooling fan is running on high speed.
Replace the high speed fan thermostat or fan motor if defective.
CGLES389ECB
PLES389EC3
CGLES389ECC
PLES389EC8
CGLES389EGL
PLES389EC9
CGLES389EES
PLES389ECC
CGLES389E38
PLES389ECG
CGLES389E9F
PLES389ECH
CGLES389EQB
PLES389EPL
GLES389FSB
PLES389EES
GLES389FSC
PLES389E39
PLES389ECF
PLES389E9E
PLES389ECP
PLES389ECE
PLES389ECL
PLES399ECF
PLES389ECE
PLES389ECG
PLES389ECS
1
Electrolux Service Flash CK076
08.30.07

Advertisement

loading

Summary of Contents for Electrolux CGLES389FB1

  • Page 1 170°F. Select a bake cycle on the EOC and check to see that the cooling fan is running on high speed. Replace the high speed fan thermostat or fan motor if defective. Electrolux Service Flash CK076 08.30.07...
  • Page 2 Step 4: Verify continuity of the wire harness and connections from the temperature sensor and safety thermostats. Electrolux Service Flash CK076 08.30.07...

This manual is also suitable for:

Cgles389f89Cgles389ecbPles389ec3Cgles389fb2Cgles389ffsCgles389ecc ... Show all