Suzuki VZ800 Service Manual page 360

Hide thumbs Also See for VZ800:
Table of Contents

Advertisement

GENERATOR NO-LOAD PERFORMANCE
• Disconnect the generator coupler. (9-10)
• Start the engine and keep it running at 5 000 r/min.
Using the multi circuit tester, measure the voltage between three
lead wires.
If the tester reads under the specified value, replace the genera-
tor with a new one.
 Generator no-load performance:
More than 70 V at 5 000 r/min (When engine is cold)
 09900-25008: Multi circuit tester set
 Tester knob indication: Voltage (~)
REGULATOR/RECTIFIER
• Remove the secondary gear case cover. (8-40)
• Disconnect the regulator/rectifier couplers.
Measure the voltage between the lead wires using the multi cir-
cuit tester as indicated in the table below. If the voltage is not
within the specified value, replace the regulator/rectifier with a
new one.
 09900-25008: Multi circuit tester set
 Tester knob indication: Diode test ()
B/R
B/R
1
B/R
0
1
B/R
0
2
B
1
B
2
B
3
B/W
1
B/W
2
1.4 V and more (tester's battery voltage)
NOTE:
If the tester reads 1.4 V and below when the tester probes are
not connected, replace its battery.
+ Probe of tester to:
B
B
B
2
1
2
3
0.4 – 0.7 0.4 – 0.7 0.4 – 0.7 0.5 – 1.2 0.5 – 1.2
0.4 – 0.7 0.4 – 0.7 0.4 – 0.7 0.5 – 1.2 0.5 – 1.2
Unit: V
B/W
B/W
1
2
0.4 – 0.7 0.4 – 0.7
0.4 – 0.7 0.4 – 0.7
WIRE COLOR
B: Black, B/R: Black with Red tracer,
0.4 – 0.7 0.4 – 0.7
B/W: Black with White tracer
0
0
ELECTRICAL SYSTEM 9-11
Y
Y
Y
B
2
B
1
B
3
B/W
1
B/R
B/R
B/W
2
1
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vz800k5M50Boulevard m50Intruder vz800

Table of Contents