4.3 Resistance-Temperature character

Value of the heat sensitive resistance of defrosting, suction air, outdoor ambient temperature,
evaporator, gas pipe and liquid pipe.
Temperature ( )
-10
-5
0
5
10
15
20
25
30
35
Value of the air discharge heat sensitive resistance
Temperature ( )
15
20
25
30
40
50
60
70
75
80
Value of the indoor ambient temperature heat sensitive resistance
Temperature ( )
15
16
17
18
19
20
21
22
Resistance value (k )
53.0
41.2
31.9
23.9
18.9
15.5
12.3
9.9
8.1
6.6
Resistance value (k )
878.5
621.4
599.9
398.6
246.4
160.4
105.3
72.1
59.5
49.3
Resistance value (k )
37.5
35.7
33.9
32.2
30.7
29.2
27.9
26.5
Temperature ( )
Resistance value (k )
40
45
50
55
60
65
70
75
80
85
Temperature ( )
Resistance value (k )
85
90
95
100
105
110
115
120
125
130
Temperature ( )
Resistance value (k )
23
24
25
26
27
28
29
30
5.5
4.6
3.8
3.2
2.7
2.3
1.9
1.7
1.4
1.2
41.5
34.8
29.6
25.0
21.7
18.7
16.0
13.8
11.9
10.3
25.3
24.1
23.0
22.0
21.0
20.0
19.1
18.2

Hide quick links: