5.2 Installation of indoor unit for console type
Tool necessary
1. Screw driver
2. Hacksaw
3. 70mm dia.hole core drill
4. Spanner(dia. 17,27mm)
5. Spanner(14,17,27mm)
6. Pipe cutter
7. Flaring tool
8. Knife
9. Nipper
10. Gas leakage detector or soap water
11. Measuring tape
12. Reamer
13. Refrigerant oil

Standard accessories

Following parts shall be field supplied
Part name
Mark
Adhensive tape
A
Pipe clip
B
C
Connecting hose
D
Insulation material
E
Putty
Drain hose
F
Fig1
330
Fig2
Fig3
Installation of indoor unit
selection of installation place
Place where it is easy to route drainage pipe
and outdoor piping.
Place ,away from heat source and with less
direct sunlight.
Place where cool and warm air could be
delivered evently to every corner of the room.
Place near power supply socket.Leave enough
space around the unit.
Place ,robust not causing vibration,where the
body can be supported sufficiently.
To prevent interference, place it at least 1m
away from other electric machines, such as
TV set, radio.
Installing
According to the dimension of the figure 2 shown,
nail two cement steel nails on the wall,Keep 2~3
mm out.then hang the back of the unit on them.
There must be no gap between the indoor unit
and wall.
Remove the front panel,then use two expansible
screws to fix the unit on the floor.As figure 3
shown.
Once refrigerant piping and drain piping connections
are complete,fill the gap of the throght hole with putty.
Attach the front panel and front grille in their orginal
positions once all connections are complete.
Shape and description
No.
Remote controller
Wire clip
Self-tapping screw
Wall hole cover
Dry battery #7
Cement steel nail
Note: There isn't connecting wire with this unit.