3 Set the ND filter (transmission factor: 6.25 %).
4 Turn ON the AGC switch on the side panel of the
camera, and turn NORM the TURBO/NORM switch
5 Shoot the all-white pattern. Check to see if the
VIDEO-OUT image level is within the specified value
range.
Subject
All white pattern
Measurement point
Image level of VIDEO OUT
Equipment
Waveform Monitor
65 ± 5 IRE (NTSC)
Specification
455 ± 35 mV (PAL)
* If there is a point where the specified value for step 5 is
satisfied while varying the lens iris within the specified
value range for step 2, the adjustment is correct.
Or, if there is a point where the specified value for step
5 is satisfied while varying the VIDEO LEVEL on the
side panel, the adjustment is correct.
4-5-7. Checking WB adjustment (3200K
preset and data take-in)
Checking ATW operation
1 Set the WB switch on the camera side panel to the
ATW-PRO position, and turn OFF the AGC and CCD-
IRIS Switches.
2 Set the C14 filter.
3 Shoot the all-white pattern. Adjust the iris diaphragm
so that the VIDEO-OUT image level is set within the
specified value range.
All white pattern
Subject
Image level of VIDEO OUT
Measurement point
Waveform Monitor
Equipment
65 ± 3 IRE (NTSC)
Specification
455 ± 20 mV (PAL)
4 Check to see if the white bright spot on the vector
scope converges to meet the specified value.
All white pattern
Subject
Measurement point
White bright spot of VIDEO OUT
Vectorscope
Equipment
Conver-
Within 30 seconds
gence time
Specifica-
tion
Within a radius of 15 % of the vector
Conver-
scope’s diameter of the origin
gence spot
(Suppose the vectorscope’s
diameter is 100 %.)
5 Remove the C14 filter and perform step 3 and step 4.
SSC-DC50A/54A