Electronic Temperature Control - Electrolux EILFU17GS Technical & Service Manual

Upright freezer
Table of Contents

Advertisement

E E l l e e c c t t r r o o n n i i c c C C o o n n t t r r o o l l
E E l l e e c c t t r r o o n n i i c c T T e e m m p p e e r r a a t t u u r r e e C C o o n n t t r r o o l l
The electronic temperature control is located on the freezer door. Temperature is factory preset to provide
satisfactory food storage temperatures. Refer to the SETTING FREEZER CONTROL Quick Reference Guide
below for more details.
Press to start or
cancel the fast
freeze feature.
Press to
decrease the
temperature
setting
Display
Priority
"HI"
Alternating "E1"
and temperature
Alternating "CE"
and temperature
Alternating "E2"
and temperature
Actual
Temperature
Set Temperature
N N O O T T E E : : The unit can reach as low as -35 degrees during the Fast Freeze Mode but ideally the mode is for
initial startup and the addition of product during restock.
N N O O T T E E : : Standard Ice Maker Production; 3.5-4 lbs/24hrs.
N N O O T T E E : : A more in depth description of the alarms is given on page 3-4.
SETTING FREEZER CONTROL
Press and
Turns the
hold for 3
temperature
seconds to
display ON or
toggle F or C
OFF.
in the display.
Indicates the
Indicates the
temperature was
door has been
above +23°F ( -9°C)
open 5 minutes
for at least one
or more.
hour.
ALARM FUNCTION TABLE
Visual Alarm
3
"HI Temp" LED ON and
mute sounds LED flashes
2
mute sounds LED flashes; 1
second set temperature, 1
second "E1"
1
mute sounds LED flashes; 1
second set temperature, 1
second "CE"
4
mute sounds LED flashes; 1
second set temperature, 1
second "E2"
6
power fail LED on and mute
sounds LED flashes
5
door ajar LED on and mute
sounds LED flashes
Press to
Press to turn the
mute
sounds ON or OFF.
audible
When the LED is ON,
alarms.
the sounds are muted.
Indicates the
power was
interrupted.
Alarm Status
Freezer temperature
over the safe limit
Fail Safe Mode
Communication Error
Stuck Key Error
Cabinet greater than 10
degrees over the SET
TEMP. at power up.
Door open for more than
5 minutes
3-2
Press and hold
for 3 seconds to
start or cancel
control lock.
Press to
increase the
temperature
setting
Action(s) Required
Press the mute sounds key
to stop the audible alarm
Check thermistor status
Press the mute sounds key
to stop the audible alarm
Check connection between
UI and ECU. Press the mute
sounds key to stop the
audible alarm
Check membrane keys.
Press the mute sounds key
to stop the audible alarm
Press the mute sounds key
to stop the audible alarm
Press the mute sounds key
to stop the audible alarm