Epson Stylus Pro 3800 Service Manual page 67

Large format color inkjet printer
Hide thumbs Also See for Stylus Pro 3800:
Table of Contents

Advertisement

Epson Stylus Pro 3800/3800C/3850/3880/3885/3890
MAINTENANCE REQUEST XXXX
When a Maintenance Request error occurs, the printer displays on the LCD a hexadecimal code of "NNNN" which correspond to the bit numbers assigned to error statuses as shown
in the table below.
Bit assignment (Binary)
0
1
2
3
4
5
1
0
(NA)
0
(NA) (NA)
0
1
(NA)
0
(NA) (NA)
0
0
(NA)
1
(NA) (NA)
0
0
(NA)
0
(NA) (NA)
0
0
(NA)
0
(NA) (NA)
0
0
(NA)
0
(NA) (NA)
0
0
(NA)
0
(NA) (NA)
0
0
(NA)
0
(NA) (NA)
Ex.
0
0
(NA)
1
(NA) (NA)
NOTE
: Ex): When "Maintenance Request 0088" is displayed.
As "0088" in hexadecimal means "1000 1000" in binary, you can find out the code is assigned to Bit-3 and Bit-7 referring to the above table. In this case, two
errors are occurring simultaneously. (Bit-3: battery exhaustion/ Bit-7: the date and time has not been set.)
TROUBLE SHOOTING
Table 3-3. Maintenance Request Errors
6
7
8
9
10
11
12
0
0
0
(NA) (NA)
0
0
0
0
0
(NA) (NA)
0
0
0
0
0
(NA) (NA)
0
0
1
0
0
(NA) (NA)
0
0
0
1
0
(NA) (NA)
0
0
0
0
1
(NA) (NA)
0
0
0
0
0
(NA) (NA)
1
0
0
0
0
(NA) (NA)
0
1
0
1
0
(NA) (NA)
0
0
Remedies for Warning Messages
XXXX
(Hexa-
Cause
13-15
decimal)
The counter of waste ink used for
(RSVD)
0001
printing margins at borderless printing
has reached the specified value.
The CR scan pass counter has reached
(RSVD)
0002
the specified value. (ink supply tube
has reached its end of life.)
The RTC backup battery becomes
(RSVD)
0008
exhausted.
The pump counter has reached the
(RSVD)
0040
specified value.
(RSVD)
0080
The date has not been set.
The RTC backup battery power has
(RSVD)
0100
temporarily dropped.
The ink cartridge installation/removal
(RSVD)
0800
counter has reached the upper limit.
The number of drives of the ink
(RSVD)
1000
selector has reached the upper limit.
(RSVD)
0088
RTC backup battery has not been set.
Revision C
Remedy
Replace the waste ink pads for borderless printing
(POROUS PAD,INK WASTE BOX, LEFT/RIGHT) with
new ones, and clear the counter using the Adjustment
Program.
Replace the tube (INK,SYSTEM,ASSY.) with a new one,
and clear the counter using the Adjustment Program.
Replace the battery with a new one, and execute RTC
initialization using the Adjustment Program.
Replace the pump cap unit (PUMP,CAP,ASSY.) with a new
one, and clear the counter using the Adjustment Program.
Execute RTC initialization using the Adjustment Program.
Wait until the power recovers.
Replace the waste ink pad (POROUS PAD,TRAY,INK
EJECT) in the cartridge holder with a new one, and clear the
counter using the Adjustment Program.
Replace the ink selector (INK,SYSTEM,ASSY.) with a new
one, and clear the counter using the Adjustment Program.
Install a battery, and execute RTC initialization using the
Adjustment Program to set date and time.
67