Audio monitor output
Stereo mini jack (× 1)
Built-in speaker output
0.5 W Monaural
Headphones output connector
Stereo mini jack (× 1)
General
Power
100 V to 240 V AC, 0.5 A to 0.3 A,
50/60 Hz
12 V DC, 1.9 A
Power consumption
Approx. 30 W (max.)
Inrush current
(1) Maximum possible inrush current
at initial switch-on (Voltage
changes caused by manual
switching):
51 A peak, 7 A r.m.s. (240V AC)
(2) Inrush current after a mains
interruption of five seconds
(Voltage changes caused at zero-
crossing):
17 A peak, 2 A r.m.s. (240V AC)
Operating conditions
Temperature
0 °C to 40 °C (32 °F to 104 °F)
Recommended temperature
20 °C to 30 °C (68 °F to 86 °F)
Humidity
30% to 85% (no condensation)
Pressure
700 hPa to 1060 hPa
Storage and transport conditions
Temperature
–20 °C to +60 °C (–4 °F to +140 °F)
Humidity
0% to 90%
Pressure
700 hPa to 1060 hPa
Accessories supplied
AC power cord (1)
AC plug holder (1)
AC adaptor (1)
Handle (1)
Arm mount bracket (1)
Screws (4)
Operating Instructions (1)
CD-ROM (1)
Using the CD-ROM Manual (1)
Optional accessories
Mounting bracket
MB-531
Mounting panel
MB-532
Monitor ENG kit
VF-510
Design and specifications are subject to change without
notice.
Note
Always verify that the unit is operating properly before
use. SONY WILL NOT BE LIABLE FOR
DAMAGES OF ANY KIND INCLUDING, BUT
NOT LIMITED TO, COMPENSATION OR
REIMBURSEMENT ON ACCOUNT OF THE LOSS
OF PRESENT OR PROSPECTIVE PROFITS DUE
TO FAILURE OF THIS UNIT, EITHER DURING
THE WARRANTY PERIOD OR AFTER
EXPIRATION OF THE WARRANTY, OR FOR
ANY OTHER REASON WHATSOEVER.
Pin assignment
PARALLEL REMOTE connector
Modular connector
(8-pin)
Pin number
Functions
1
Designating SDI 1 input signal
2
Designating HDMI input signal
3
Designating composite input signal
4
Setting tally lamp green ON/OFF
5
GND
6
Setting tally lamp red ON/OFF
7
Selecting over scan
8
Selecting normal scan
You can allocate functions using the REMOTE menu
(see page 30).
Note
Switching functions continuously allows at least 200
msec to do so. Otherwise, it may not switch correctly.
Wiring required to use the Remote Control
Connect the function you want to use with a Remote
Control to the Ground (Pin 5).