EKB3 is a keyboard intended to use with GSM alarm and management system ESIM264. Main EKB3 keyboard functions are: • arm and disarm security system • arm and disarm STAY mode • configure system parameters • display information with LED indicators • inform about system status via sound signaler The keyboard uses two password levels - user and administrator. System configuration can be performed by entering administrator password and using programing commands. ESIM264 allows to connect up to 4 EKB3 keyboards. Integrated sound signaler informs about successful/unsuccessful functions performance, informs about entry and delay time countdowns. CONTENT 1. Package content ................................x 2. Device installation ................................x 3.
BACK SIDE Fig. No. 1 2. Disconnect security system ESIM264 power supply and backup battery before connecting the wires. 3. Connect keyboard connectors to ESIM264. Accordingly, AUX+ to AUX+, AUX- to AUX-, Y to Y, G to G. Keyboard Z1 zone connect to keyboard COM with 5,6kΩ resistor. Zone Z2 is not active and there is no need to connect it. Configure DIP switches (see chapter 3.4). 4. Infix the keyboard into the holder. NOTE: Pay attention to the tamper when fixing the keyboard to the keyboard holder. It must be properly pressed. 5. Turn on ESIM264 power supply. 4. EKB3 keyboard is ready to use. 3. Technical specifications 3.1 Electrical and mechanical characteristics Power supply 12-14V 150mA max Maximum keyboard connection cable length 100 m. Dimensions 140x100x18mm Range of Operating Temperatures 0...+55ºC...
BYPS BYPS INST TAMPER AUX- AUX+ CODE DIP SWITCH Fig. No. 2 Fig. No. 3 TAMPER 3.4 DIP switches AUX- DIP switches are used to set keyboard address. ESIM264 allows to connect up to 4 EKB3 keyboards. Every keyboard must have different address (two keyboards cannot be configured with the same AUX+ DIP switch combination). Possible configuration combinations are displayed in the table below. Fig. No. 4 DIP SWITCH NOTE: Third switch is not active and its position is irrelevant. Address Keyboard 1 Keyboard 2 Keyboard 3 Keyboard 4...
Trouble Tamper Backup battery Main power Time High zones* GSM connection * High zones are troubled zones above 12. If yellow LED called SYSTEM is blinking means that there are violated zones or tampers above 12. To check which zone is violated use command [CODE1], where CODE means a button named CODE. To check which tamper is violated use command [CODE2], where CODE means a button named CODE. The keyboard will display a code of violated zone. To know which zone or tamper above 12 is violated, use a formula B+A, e.g. if system displays zones 5 and 10, means that violated zone is 30+5=35. Zone number 1 = 1 Zone number 7 = 12 Zone number 2 = 2 Zone number 8 = 18 Zone number 3 = 3 Zone number 9 = 24 Zone number 4 = 4 Zone number 10 = 30 Zone number 5 = 5 Zone number 11 = 36 Zone number 6 = 6 Zone number 12 = 42 4.3 Bypassing zones To bypass any zone use the command [BYPSxxyyyy#], where BYPS - means a button named BYPS, xx – zone number and yyyy – key- board password. Use the same command to enable bypassed zones. The zone can be bypassed only for temporary period and after arming-disarming the system it will be active again. 4.3 Configuration commands To use configuration commands user have to enter administrator code. Administrator code can be entered to the system with com- mand [*XXXX#], where XXXX – administrator code. When administrator code is entered successfully the red LED called ARMED starts blinking. USER MANUAL EKB3 V1.0...
4.3.1 Users commands Allow Only When this function is enabled, the system reacts to the SMS messages-commands that are Preset Users sent only from registered telephone numbers. If this function is disabled, the device can be controlled by all users who know the number of the SIM card inserted in the device, control commands and the main password. Factory default setting – enabled. Enter code 12 and function: EKB3 Enabled – [120#] Disabled - [121#] When this function is enabled, in the case of an alarm, the system simultaneously sends SMS All SMS messages to all entered users. By default this function is disabled. When this function is disabled, SMS messages are delivered in a sequence starting with the first user (User1). The message will be sent to the next user only in the case the device does not receive a confirmation about a successful SMS message delivery to the first recipient. Enter code 21 and function: EKB3 Disabled – [210#] Enabled - [211#] Inform about When this function is enabled, the system sends information messages to the main user (User1) about armed/disarmed security system. By default this function is disabled. Arming/Disarming Enter code 22 and function: EKB3 Disabled – [220#]...
Page 7
Alarm Enter code 31 and function: EKB3 Disabled – [310#] Enabled - [311#] Indicates partition in which user is assigned. User Partition Enter code 59, user number and partition: EKB3 User 1 – [5901x#] User 2 – [5902x#] User 3 – [5903x#] User 4 – [5904x#] User 5 – [5905x#] where x – 0: partition 0, 1: partition 1. USER MANUAL EKB3 V1.0...
Indicates partition in which iButton key is assigned. iButton Partition Enter code 60, iButton number and partition: EKB3 iButton 1 – [6001x#] iButton 2 – [6002x#] iButton 3 – [6003x#] iButton 4 – [6004x#] iButton 5 – [6005x#] where x – 0: partition 0, 1: partition 1. 4.3.2 Password commands The main 4 digit SMS password which is used for system configurations and control via SMS SMS Password messages. By default, password is 0000, which is NECESSARY to change. Enter code 14 and new SMS password: EKB3 [14xxxx#] where xxxx –...
Page 9
This function deletes keyboard password. Password Enter code 65 and keyboard password: EKB3 [65xxxx#] where xxxx – keyboard password. The 4 digits administrator password which is used to configure system settings with a key- Admin Password board. By default, this password is 1470, which is recommended to change. Enter code 16 and new administrator password: EKB3 [16xxxx#] where xxxx – 4 digits new administrator password. USER MANUAL EKB3 V1.0...
4.3.3 Zones commands When ATZ mode (zone duplication) is enabled, the zone number is increased to 12. By de- ATZ Mode fault, ATZ mode is disabled. Enter code 28 and function: EKB3 Disabled – [280#] Enabled - [281#] Arm-Disarm Choose the zone which will work in Arm-Disarm mode. With this zone security system can be activated/deactivated with a “ low” level impulse which is not shorter than 3 seconds. This mode By Zone can be set only for one zone. No resistance is connected when using 6 zone connection type and the input must be NO (normally open). If ATZ mode is enabled the impulse is transmitted through resistance. If Z2-Z6 zones are used, the impulse should be transmitted through 5.6k resistance, if Z7-Z12 zones - the impulse should be transmitted through 3.3k resistance. Enter code 34 and zone number: EKB3 Zone 1 – [3401#] Zone 2 – [3402#] Zone 3 – [3403#] … Zone 12 - [3412#] Disabled – [3400#] In the environment of ESIM264 Configuration Tool the user must specify the mode...
Page 11
• Type5 – Tamper and 5,6KΩ end of line resistor and 5,6KΩ end of line resistor with normally closed contact and 3,3KΩ end of line resistor with normally closed contact. This type of connection is used for ATZ mode. Enter code 39 and Zone mode: EKB3 Type4 - [391#] Type5 - [392#] Zone Status parameter is used to enable/disable zones. Zone Status Enter code 52, zone number and function: EKB3 Zone 1 – [5201x#] Zone 2 – [5202x#] Zone 3 – [5203x#] Zone 44 – [5244x#] where x – 0: disabled, 1: enabled. USER MANUAL EKB3 V1.0...
Page 12
Follow – this zone doesn't react to violations during Delay time. Zone Type Instant - when this zone is violated, immediately cause an alarm. Delay - doesn't react to violations in time period which is used to enter security password. 24H - this zone is active all the time, even when the system is disarmed. Fire - this type of zone is used to connect smoke detectors. Silent - this zone works as 24H zone and when it is violated, the system doesn't turn on the siren. Enter code 52, zone number and function: EKB3 Follow - [53xx1#] Instant - [53xx2#] 24H - [53xx3#] Delay - [53xx4#] Fire - [53xx5#] Silent - [53xx6#] where x – zone number. Parameter range from 01 to 44 This field is used to configure the time which is dedicated to disarm the security system Entry Delay when users enters in the specified Delay zone. If system will not be disarmed in time, the it...
Page 13
EKB3 Zone 1 – [5601x#] Zone 2 – [5602x#] Zone 3 – [5603x#] Zone 44 – [5644x#] where x – 0: disabled, 1: enabled. Indicates partition in which zone operates. Zone Partition Enter code 57, zone number and partition: EKB3 Zone 1 – [5701x#] Zone 2 – [5702x#] Zone 3 – [5703x#] Zone 44 – [5744x#] where x – 0: partition 0, 1: partition 1. USER MANUAL EKB3 V1.0...
4.3.4 Monitoring station commands When this function is enabled, the system generates CONTACT ID messages and delivers CID Enable them to monitoring stations. When this function is disabled, the system operates in normal mode, i. e., delivers messages only to registered users (other configurations in MS Settings section becomes inactive). Enter code 23 and function: EKB3 Disabled – [230#] Enabled - [231#] Configure which Contact ID messages will be delivered to monitoring station. By default, CID Messages all these messages are activated. Alarm/Restore Event – the messages about system alarm and restore events. External Power Loss/Restore Event – the messages about external power supply loss and restore events. Akum Status Event – the messages about backup battery flat status. Armed Event - the messages about security system arming events. Disarmed Event - the messages about security system disarming events.
Page 15
– 0: disabled, 1: enabled. Configure monitoring station phone numbers. The first phone number is the main moni- Monitoring Station toring station number and the other two are alternative. Phone numbers can contain from Phone Numbers 7 to 15 numbers. Enter code 26, phone number (01-03) and monitoring station EKB3 phone number: [26xxyyyyyyyyyyy #] where xx – phone number, yyyyyyyyyyy – monitoring station pho- ne number. USER MANUAL EKB3 V1.0...
Page 16
A device access number which is used by the Monitoring station to determine the monito- Account ring object. Initial account number (9999) must be changed. Enter code 27 and account number: EKB3 [27xxxx#] where xxxx – account number. This field is used for indicating the number of attempts the system tries to call on the telep- Attempts hone number of the Monitoring Station if the initial call was unsuccessful. If all the attempts were unsuccessful the system goes to the next Monitoring Station number in the hierarchy. If the call to the last telephone number Alternate Num2 in the hierarchy was unsuccessful, the calls are made from the beginning starting with the main Monitoring Station number ( TelNumber1 ). By default settings, number of these calls is 5. Enter code 37 and number of attempts: EKB3 [37xx#] where xx – number of attempts. IP address of the router that the server is connected to. Server IP...
Page 17
IP: 1.10.100.254 Primary DNS server IP address. DNS2 Enter code 42 and DNS2 IP address numbers: EKB3 {42xxxxxxxxxxxx#] where xxxxxxxxxxxx – DNS2 IP address numbers, e.g. 001010100254 for IP: 1.10.100.254 System can work via TCP or UDP protocol. Protocol Enter code 43 and function: EKB3 TCP - [430#] UDP – [431#] USER MANUAL EKB3 V1.0...
Page 18
Router port number used for communicating with the device. Server Port Enter code 44 and port number: EKB3 [44x#] where x – port number. Parameter range from 0 to 65535. Local port number used for communicating with the device. Parameter range from 0 to 65535. Local Port Enter code 45 and port number: EKB3 [45x] where x – port number. Period time of sending CONTACT ID protocol messages to monitoring station. The recommen- Test Period ded value using GPRS Network is 60 and for GSM connection – 0.
Enter code 19 and degrees in Celsius: EKB3 [19xx#] where xx – number of degrees in Celcius. Temperature sensors maximum marginal temperature. The temperature is measured in de- grees Celsius. Type zeros if the temperature sensor is not used or if you don't want to let the system to react to the temperature indication. Enter code 20 and degrees in Celsius: EKB3 [20xx#] where xx – number of degrees in Celcius. USER MANUAL EKB3 V1.0...
Temperature When this function is enabled, system sends the information by SMS messages about tempe- rature deviation from the set values. By default, this function is enabled. Limit Info SMS Enter code 50 and function: EKB3 Disabled – [500#] Enabled - [501#] 4.3.6 Other commands This parameter is used for setting the time of device alarm siren sound after the alarm is acti- Alarm time vated. The time is indicated in minutes. Factory default setting – 1 minute. Parameter range from 00 to 10. Enter code 10 and count of minutes: EKB3 [10xx#] where xx – minutes. The system ESIM264 periodically sends information messages about device status. The user Info SMS scheduler can specify the frequency and time of these continuous messages. Time – specifies the time at which information message will be delivered. Parameter range from 01 to 23. Period – spe-...
Page 21
'+' . Users phone numbers can contain from 7 to 15 numbers. Enter code 17, user number and phone number: EKB3 [17xxyyyyyyyyyyy#] where xx – user number, yyyyyyyyyyy – user phone number. Enable this function if you want to register iButton keys to the system. After registering iButton New iButton keys keys, this function must be disabled. Write Enable Enter code 18 and function: EKB3 Enabled – [180#] Disabled - [181#] USER MANUAL EKB3 V1.0...
Page 22
A short siren informs about enabled/disabled security system. Bell Squawk Enable Enter code 29 and function: EKB3 Disabled – [290#] Enabled - [291#] When this function is enabled, users will be informed with sound signal of the keyboard spe- Chime Enable aker about any triggered Delay zone sensors even when the system security is not activated. By default, this function is enabled. Enter code 32 and function: EKB3 Disabled – [320#] Enabled - [321#] Using Module Enable this function when module EPGM8 is used. The number of outputs will be increased to 12 units. EPGM8 Enter code 33 and function: EKB3 Disabled – [3302#] Enabled - [3312#]...
Page 23
Disabled – [360#] Enabled - [361#] This function enables and disables automatic output control. Specific automatic output Control Status control configuration can be done only with software “ELDES Configuration Tool”. Enter code 49 and number of attempts: EKB3 1 – [4901x#] 2 – [4902x#] 3 – [4903x#] … 10 - [4916x#] where x – 0: disabled, 1: enabled. USER MANUAL EKB3 V1.0...
Page 24
Indicates partition in which operates the keyboard. Keyboard Partition Enter code 51 and function: EKB3 Keyboard 1 – [5101x#] Keyboard 2 – [5102x#] Keyboard 3 – [5103x#] Keyboard 4 – [5104x#] where x – 0: partition 0, 1: partition 1. This function resets all device parameters to default values. Reset To Default Enter code 62 and administrator password: EKB3 [62xxxx#] where xxxx – administrator password. This function enables to change date and time settings.