Dell 3333dn Service Manual page 64

Hide thumbs Also See for 3333dn:
Table of Contents

Advertisement

Error
HD/Config ID Mismatch
849.01
Engine software service errors
900.xx
RIP software error
902.xx
Engine software error
903.xx
Paperport link driver error
904.xx
Interface violation by RIP
905.xx
Interface violation by paperport device
906.xx
RIP interface drive error
DC pick motor errors
910.xx
DC pick motor stall
911.xx
DC pick motor excessive PWM
912.xx
DC pick motor below speed
913.xx
DC pick motor over speed
914.00
DC pick motor error
914.01
Lost encoder feedback
Transfer service errors
917.xx
Transfer service error
Fuser service errors
920.00
Under temperature during steady state control.
921.00
Under temperature during standby control.
922.00
Fuser failed to ramp to target temperature
923.00
Fuser is over temperature.
924.00
Open thermistor check.
925.xx
Wrong fuser installed. The fuser type stored in the
cartridge ID does not match the actual fuser installed in
the printer.
Fan service errors
927.00
Service fan error
927.33
Service fan error (Controller board cooling fan)
2-28
Service Manual
Description
Action
A device has a hard drive installed, but its
Configuration ID indicates that a hard drive
shouldn't be present.
Turn off MFP for 10 seconds and restart. If error
re-occurs, replace controller board.
Replace the controller board. See
board service check" on page 2-35
Replace the transfer roll. See
service check" on page
2-54.
Replace the fuser. See
"Fuser service check"
on page
2-39.
Replace the fan. See
"Cooling fan service
check" on page
2-37.
Replace the controller board fan. See
"Controller board fan" on page
"Controller
"Transfer roll
4-14.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3335dn

Table of Contents